EasyManua.ls Logo

PeakTech 2015 A - Page 43

PeakTech 2015 A
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
3.8. Capacitance
Range
Resolution
Accuracy
60 nF
0.01nF
3,5% + 20 dgt.
600 nF
0.1nF
6 µF
0.001µF
60 µF
0.01µF
600 µF
0.1µF
5,0% + 10 dgt.
Accuracy applies to: 10% to 100% of Range
Overload protection: 250V DC/AC
rms
Large capacitance response time:≥1µF about 3s
Measurement error does not include lead capacitance.
3.9. Diode
Range
Resolution
Accuracy
Test-
current
Open
circuits
volts
2 V
1 mV
5%
0.4 mA
ca. 3.3
V DC
Overload protection: 250V DC/AC
rms
3.10. hFE Triode Test
Range
Function
Test current
VCE
0 - 1000
NPN or PNP
ca. 10 µA
Ca. 1.5V
3.11. Continuity check
Audible continuity threshold: Less than 50 ( 20)
Test Current: ca. 0,4 mA
Open Circuit Voltage: ca. 1 V DC
Overload protection: 250V DC/AC
rms