Page 21Peavey Electronics Corporation
MM
-8802 Control Device Features, continued
FULL-SCALE INPUT SENSITIVITY DIALOG BOX (Active for MM-Line 4 Only.) These
buttons toggle the analog input sensitivity between +12, +18, +24 and +30 dBu for each chan-
nel. These buttons are mutually exclusive. Only one button can be active at a time per chan-
nel. (Functional only with MWare
3.1.2 or X-Frame
88 Version 2, see pages 16-19.)
FULL-SCALE OUTPUT DIALOG BOX These buttons toggle the full-scale analog output
level between +6, +12, +18 and +24 dBu for each channel. These buttons are mutually exclu-
sive. Only one button can be active at a time per channel. (Functional only with MWare
3.1.2 or X-Frame 88 Version 2, see pages 16-19.)
RAW INPUT (CV CAL... DIALOG BOX) This control indicates the actual value as deter-
mined by an external control. Use this indicator to see exact performance of external
devices. The range is 0-255. There is an indicator for each channel. (See page 37.)
SET MAX BUTTON (CV CAL...DIALOG BOX) This is a momentary button used to set
the minimum, or lowest value of an external control’s range. The indicator above displays
SET MIN value. The range of display is 0-255. There is a button for each channel. (See page
37.)
SET MIN BUTTON (CV CAL...DIALOG BOX) This is a momentary button used to set the
maximum, or highest value of an external control’s range. The indicator above displays SET
MAX value. The range of display is 0-255. There is a button for each channel. (See page 37.)