7. FUNCTIONS AND PROGRAMMING
MAIN VISUALIZATIONS:
When EVOLUTION turns on the display visualizes the following sequence:
electric pump
EVOLUTION v 1.0
➞
PEDROLLO
www.pedrollo.com
➞
Model 50Hz
es. m/2.2
After the sequence above the display appears as follows:
230v 0.0A 1.0@
Man ( ) Aut (*)
This screen allows to visualize the electrical measures detected by EVOLUTION in each mo-
ment:
• 230V= power supply voltage detected;
• 0.0A= corrent absorbed by the load connected;
• 1.0ϕ = power factor (cos-) of the load connected;
• Man (*)= EVOLUTION on manual mode;
• Aut (*)= EVOLUTION on automatic mode.
LOAD ACTIVATION ON MANUAL MODE:
Push the
button and the display shows
230v 0.0A 1.0@
Man (*) Aut ( )
to activate the load,
push the
button and check the load is disabled when the led lights up after
releasing the
button .
On manual mode the load is activated and it by-passes all the alarms, but in case of a failure
the display ashes and the description of the alarm appears when pushing the
button.