REPAIR INSTRUCTIONS
TYPE AE PUMPS
MECHANICAL SEALED
Read this entire bulletin
before attempting to repair this pump. For installation
and operation refer to instruction bulletin 2880549.
Properly installed, your Peerless Pump will give you
satisfactory, dependable service. We urge that you care-
fully read these step-by-step instructions, to simplify any
problems of installation, operation or repair.
Failure to read and comply with installation and
operating instructions will void the responsibility of the
manufacturer and may also result in bodily injury as well
as property damage.
This bulletin is intended to be a permanent part of your
pump installation and should be preserved in a
convenient location for ready reference. If these
instructions should become soiled, obtain a new copy
from Peerless Pump Company include pump model
and/or serial number with your request.
Peerless Pump Company
These instructions are prepared for a pump with grease
or oil lubricated bearings and mechanical seals in the
stuffing boxes. Optional features are covered by
separate instructions sheets which are furnished when
the equipment supplied includes these features.
Many models have suffix letters in the model number.
These suffix letters have been intentionally omitted from
Table I. However, when ordering repair parts, provide
the complete model number including suffix letters and
the pump serial number; both are stamped on the pump
nameplate.
4851959
Rev. 11/93
Question and Answer IconNeed help?

Do you have a question about the Peerless Pump AE Series and is the answer not in the manual?

Summary

Warranty Information

Pump Disassembly Procedures

Coupling Halves Disengagement

Instructions for disengaging coupling halves.

Pump Disassembly Steps

Detailed steps for disassembling the pump casing and components.

Rotating Element Disassembly

Procedure for disassembling the rotating element, including bearings and covers.

Part Cleaning and Preparation

Guidelines for cleaning all metal parts and specific instructions for ball bearings.

Removal or Replacement of Components

Guidance on when to remove or replace specific pump components.

Inspection and Repair Procedures

Component Inspection

Visual inspection of parts for damage, focusing on wear rings and mechanical seal faces.

Repair Guidelines

Procedures for repairing or replacing worn or damaged casing rings and impeller rings.

Pump Reassembly Procedures

Rotating Element Reassembly

Steps for reassembling the rotating element, including impeller, bearings, and seals.

Pump Casing and Component Assembly

Instructions for assembling the pump casing, bearing caps, and shaft sleeves.

Lubrication and Maintenance

Lubricating Instructions

Guidelines for oiling bearings, including initial fill and oil change frequency.

Troubleshooting Common Issues

Pump Performance Problems

Diagnosing and resolving issues like low pressure, incorrect rotation, and loss of prime.

Vibration and Noise Issues

Troubleshooting causes for pump vibration and noise, such as misalignment or worn bearings.

Peerless Pump AE Series Specifications

General IconGeneral
SeriesAE
TypeEnd Suction
ApplicationIndustrial, commercial, municipal water supply, irrigation, HVAC
Operating TemperatureUp to 250°F (121°C)
Casing MaterialCast iron
Impeller MaterialBronze
SealingMechanical Seal
StandardsANSI

Related product manuals