Pinnacle
®
Gas Boilers
Peerless
®
Stainless Steel
Installation,
Operation &
Maintenance
Manual
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
If the information in this manual is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
WARNING
As an ENERGY STA R
®
Partner, PB Heat, LLC has
determined that this product meets the
ENERGY STA R
®
guidelines for energy efficiency.

Questions and Answers

  • C
    Cheryl GuerraJul 26, 2025
    What to do if the water pressure switch is open on my PEERLESS Boiler?
    • R
      Regina BarryJul 26, 2025
      If the water pressure switch on your PEERLESS Boiler is open, ensure the system pressure exceeds 10 psig. Also, check for leaks in the system piping. To check the switch operation, apply a jumper. Replace the switch if it's not functioning correctly.
  • M
    Michael CopelandAug 1, 2025
    How to fix a high limit exceeded error on a PEERLESS Gas?
    • K
      Karen ThomasAug 1, 2025
      If the high limit has been exceeded on your PEERLESS Boiler, first check the circulation pump operation. Then, ensure adequate flow through the boiler by checking the status menu, making sure there's less than a 50°F rise from the return thermistor to the supply thermistor. Finally, replace the switch if it's faulty.
  • S
    Susan Levine MDAug 7, 2025
    What to do if the blocked vent pressure switch is open in my PEERLESS Gas?
    • N
      Nicole JacksonAug 7, 2025
      If the blocked vent pressure switch is open on your PEERLESS Boiler, make sure that the vent is not blocked. Check the switch operation by applying a jumper. Replace the switch if it is not functioning properly.
  • K
    Kayla PonceAug 13, 2025
    Why is the combustion fan speed high on my PEERLESS Boiler?
    • J
      James PopeAug 13, 2025
      If the combustion fan speed is too high on your PEERLESS Boiler, begin by checking the combustion air fan wiring. If the wiring is correct, consider replacing the combustion air fan. If problems persist, the control board may need replacement.
  • T
    Troy RiosSep 10, 2025
    Why is the combustion fan speed low on my PEERLESS Gas Boiler?
    • C
      cstrongSep 12, 2025
      If the combustion fan speed is low on your PEERLESS Boiler, first check the combustion air fan wiring. If the wiring is correct, consider replacing the combustion air fan. If problems persist, the control board may need replacement.

Summary

Peerless Pinnacle Gas Boilers: Installation, Operation & Maintenance

Safety Warning: Fire and Explosion Hazards

Critical warnings about fire and explosion risks if the manual is not followed.

Gas Leak Response Procedures

Steps to follow if a gas leak is detected, emphasizing safety and contacting authorities.

Preinstallation Requirements

Codes and Regulations Compliance

Adherence to state, local, ASME, NFPA, and ANSI codes for boiler installation.

Boiler Setup Procedures

Water Piping and Controls

Gas Piping Installation and Sizing

General Gas Piping Regulations

Follow local codes and the National Fuel Gas Code for all fuel piping.

Fuel Line Sizing Calculations

How to calculate gas rates and size fuel lines using input rates and heating values.

Gas Supply Piping Installation

Procedures for installing sediment traps, service valves, and maintaining regulator distance.

Gas Supply Piping Operation

Steps for purging air from gas lines and checking supply pressure.

Main Gas Valve Operation

Illustrations of the gas valve assembly and instructions for adjusting the throttle screw.

Venting, Air Intake, and Condensate Management

General Venting and Air Intake Rules

Install per codes; boiler is direct vent; warning about positive pressure in the vent system.

Approved Venting Materials

Lists approved non-foam core pipe materials and warns against foam core for exhaust.

Electrical Wiring and Connections

Boiler Safety Interlock Features

Details safety switches like low water, high temperature, and blocked vent limits.

Start-Up Procedures

Lighting and Operating Instructions

Safety information and step-by-step guide for lighting and operating the appliance.

Boiler Lighting and Operation

Detailed safety warnings and procedures for starting the boiler and setting the thermostat.

Troubleshooting Boiler Faults and Errors

Boiler Error Code Identification

Explains how error codes are displayed and lists common errors with corrective actions.

Boiler Fault Code Identification

Identifies fault codes displayed by the controller and provides troubleshooting guidance.

Boiler Fault Code Resolution

Detailed corrective actions for various boiler fault codes, including sensor and fan issues.

Boiler Maintenance Schedule

PEERLESS Gas Boiler Specifications