Table of Contents

Questions and Answers

  • T
    Tommy KellySep 19, 2025
    How to troubleshoot high stack temperature in my PEERLESS Boiler?
    • W
      Wendy JohnsonSep 22, 2025
      If the flue pipe is hot, check the flue temperature and compare it to the values shown in Table 8.5. Also, check for proper gas input and combustion readings, and inspect for a dirty heat exchanger. If the flue pipe is not hot, check the flue sensor and harness.
  • V
    Victor NormanAug 25, 2025
    How do I fix a blocked condensate drain on my PEERLESS PureFire PF-50?
    • K
      Kristine MendozaAug 25, 2025
      If your PEERLESS Boiler shows a 'BLOCKED CONDENSATE DRAIN' error, check the condensate tanks, hoses, condensate switch, and harness.
  • J
    jeffrey67Aug 26, 2025
    What to check if my PEERLESS PureFire PF-50 shows a low water error?
    • M
      Michael PhillipsAug 26, 2025
      Check the boiler water level, low water cut-off, and harness. If a LWCO is not used, a jumper should be placed between terminals #9 and #10, LWCO Contact.
  • S
    Steven KingAug 27, 2025
    What to do if there is a false flame detected before ignition in my PEERLESS Boiler?
    • A
      anita09Aug 27, 2025
      If you're experiencing a false flame detected before ignition with your PEERLESS Boiler, check the flame sensor and igniter to ensure there are no shorts to ground.
  • R
    Robert GonzalezSep 23, 2025
    Why is the return temperature higher than the supply temperature in my PEERLESS PureFire PF-50?
    • D
      davisjamesSep 23, 2025
      Check the system piping to ensure that the water is entering the return connection and exiting the supply connection.
  • M
    marshallmichaelSep 23, 2025
    What to do if my PEERLESS PureFire PF-50 has a blocked condensate drain?
    • D
      David TurnerSep 23, 2025
      Check the condensate tanks, hoses, condensate switch, and harness.
  • J
    Joan AndersonSep 10, 2025
    How to troubleshoot stack sensor short error on PEERLESS PureFire PF-50 Boiler?
    • T
      Tracy SmithSep 10, 2025
      If your PEERLESS Boiler displays the error 'STACK SENSOR SHORT', check the harness and sensor.
  • J
    Jessica FranklinSep 12, 2025
    How to fix DHW sensor short error on PEERLESS PureFire PF-50?
    • R
      Ray JohnsonSep 12, 2025
      If your PEERLESS Boiler displays the error 'DHW SENSOR SHORT', check the harness and sensor.
  • V
    Veronica BaileySep 3, 2025
    How to troubleshoot high return temp on PEERLESS PureFire PF-50 Boiler?
    • C
      Christopher CarterSep 4, 2025
      If your PEERLESS Boiler displays 'HIGH RETURN TEMP', check for reversed supply and return piping or a pump installed backwards.
  • E
    eric95Sep 1, 2025
    Why is the return higher than supply on my PEERLESS Boiler?
    • C
      Charles ChenSep 2, 2025
      If you see 'RETURN HIGHER THAN SUPPLY' on your PEERLESS Boiler, check the system piping to ensure water enters the return connection and exits the supply connection correctly. Also, compare the supply thermistor reading to the temperature gauge; if they don’t match, replace the supply thermistor.

PEERLESS PureFire PF-50 Specifications

General IconGeneral
AFUE95%
Fuel TypeNatural Gas or Propane
Boiler TypeCondensing
Heat Exchanger MaterialStainless Steel
Input BTU/h50, 000
Output BTU/h47, 500
Efficiency95%
Weight130 lbs
Vent Diameter2" or 3"
Water Connections1" NPT