PEERLESS PureFire PF-50 - User Manual

PEERLESS PureFire PF-50
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PUREFIRE
®
REV
2
Boilers
PF-50 PF-80 PF-110 PF-140 PF-210 PF-399
Gas
Installation,
Operation &
Maintenance
Manual
As an ENERGY STAR
®
Partner, PB Heat, LLC has determined that
this product meets the ENERGY STAR guidelines for energy efficiency.
®

Table of Contents

Questions and Answers

  • J
    Jessica FranklinSep 12, 2025
    How to fix DHW sensor short error on PEERLESS PureFire PF-50?
    • R
      Ray JohnsonSep 12, 2025
      If your PEERLESS Boiler displays the error 'DHW SENSOR SHORT', check the harness and sensor.
  • J
    Joan AndersonSep 10, 2025
    How to troubleshoot stack sensor short error on PEERLESS PureFire PF-50 Boiler?
    • T
      Tracy SmithSep 10, 2025
      If your PEERLESS Boiler displays the error 'STACK SENSOR SHORT', check the harness and sensor.
  • S
    Scott WeaverSep 9, 2025
    How to fix return sensor short error on PEERLESS Boiler?
    • A
      Andrew PhillipsSep 9, 2025
      If your PEERLESS Boiler displays the error 'RETURN SENSOR SHORT', check the harness and sensor.
  • R
    rodriguezsamanthaSep 8, 2025
    How do I fix supply sensor short error on PEERLESS PureFire PF-50 Boiler?
    • J
      Jennifer Stone MDSep 8, 2025
      If your PEERLESS Boiler displays the error 'SUPPLY SENSOR SHORT', check the harness and sensor.
  • S
    Sheila AcostaAug 23, 2025
    How to troubleshoot ignition error on PEERLESS PureFire PF-50?
    • L
      Lawrence FarrellAug 23, 2025
      If you are experiencing an ignition error with your PEERLESS Boiler, follow these steps: 1. Watch the igniter through the observation window. 2. If no spark is present, check the spark electrode for the proper 3/16" gap. 3. Remove any corrosion from the spark electrode with abrasive. 4. If spark is present but no flame, check the gas supply to the boiler. Check for high or low pressure. 5. If there is a flame, check the flame signal ignition log in the Installer Menu. If values for flame signal are less than 3.1 µA, check wiring connections and clean the harness connector at the control. 6. Determine if gas valve is opening by monitoring gas pressure. 7. Check gas pressure.
  • U
    ubaldwinSep 6, 2025
    How to fix return sensor not connected error on PEERLESS PureFire PF-50 Boiler?
    • L
      leerandySep 6, 2025
      If your PEERLESS Boiler displays the error 'RETURN SENSOR NOT CONNECTED', check the harness and sensor.
  • U
    ujohnsonSep 5, 2025
    How to fix supply sensor not connected error on PEERLESS Boiler?
    • M
      Mary SimmonsSep 5, 2025
      If your PEERLESS Boiler displays the error 'SUPPLY SENSOR NOT CONNECTED', check the harness and sensor.
  • V
    Veronica BaileySep 3, 2025
    How to troubleshoot high return temp on PEERLESS PureFire PF-50 Boiler?
    • C
      Christopher CarterSep 4, 2025
      If your PEERLESS Boiler displays 'HIGH RETURN TEMP', check for reversed supply and return piping or a pump installed backwards.
  • B
    Blake GonzalezSep 2, 2025
    What to do for false flame detected after shutdown on PEERLESS PureFire PF-50 Boiler?
    • B
      bharrisSep 2, 2025
      If your PEERLESS Boiler displays 'A19 - FALSE FLAME DETECTED AFTER SHUTDOWN', check the flame sensor and igniter to ensure there is no short to ground. This error may also indicate that the gas valve isn’t closing completely.
  • E
    eric95Sep 1, 2025
    Why is the return higher than supply on my PEERLESS Boiler?
    • C
      Charles ChenSep 2, 2025
      If you see 'RETURN HIGHER THAN SUPPLY' on your PEERLESS Boiler, check the system piping to ensure water enters the return connection and exits the supply connection correctly. Also, compare the supply thermistor reading to the temperature gauge; if they don’t match, replace the supply thermistor.

PEERLESS PureFire PF-50 Specifications

General IconGeneral
AFUE95%
Fuel TypeNatural Gas or Propane
Boiler TypeCondensing
Heat Exchanger MaterialStainless Steel
Input BTU/h50, 000
Output BTU/h47, 500
Efficiency95%
Weight130 lbs
Vent Diameter2" or 3"
Water Connections1" NPT