INSTALLATION MANUAL
Rev. 01-19
Thank you for choosing a PEGO steam distributor for immersed electrodes humidifiers
EASYSTEAM.
The complete reading of this manual will allow you to perform a correct installation.
We therefore recommend that you keep this manual.
GENERALITY
A good distribution of steam, to obtain the desired level of humidity in any environment,
is linked to two main variables: the amount of steam introduced into the environment and
its distribution.
In fact, when the steam is introduced into an environment in a non-homogeneous way, it tends to
create saturated zones and zones deficient in humidity, causing a phenomenon of excessive
condensation and the difficult control of the production of steam and triggering a "pendulum"
effect. It is advisable to introduce the steam with a PEGO steam distributor, inserting it into the air
duct or in front of a fan unit where you want to put the steam directly in an environment without an
air duct.
MAIN INSTALLATION WARNINGS
1. Use only PEGO HUMIDIFIERS steam tube or other tube with certification that guarantees its
use in the presence of high temperatures without internal vulcanization processes and release
of harmful substances.
2. The steam tube must be of a suitable diameter and must be firmly fixed to the steam
distributor with a hose clamp.
3. Do not make bottlenecks, siphons or lengths greater than 5 meters.
4. Do not make sharp bends or at 90 °. The minimum bending radius (at 20 ° C) is 115mm for
the UMITUBVAP25M tube and is 180mm for the UMITUBVAP40M tube.
5. If rigid pipes are used, use only copper or stainless steel pipes and connect the rigid steam line
to the steam distributor, using a small portion of steam tube, fixed with the appropriate
clamps.
6. The provisions of points 2, 3 and 4 also apply to rigid pipes.
7. To facilitate the installation of steam distributors and for control reasons, an inspection hole of
sufficient size must be provided inside the air duct.
8. Within the humidification distance, the ventilation duct should be watertight.
9. The air ducts that pass through cold environments must be insulated so as to avoid
condensation of the humidified air on the walls of the duct.
10. Unfavorable fluid dynamic conditions inside the air duct (eg. due to obstacles, tight bending
radii, etc.) can cause condensation of the humidified air.
11. For any questions, please contact the Pego service center, listed on the back of this manual.