MANUALE D’USO – USER MANUAL
REPLACING THE CYLINDER
The only consumption element of the humidifier is the cylinder when the electrodes are
worn due to machine functioning or they cannot eliminate the scaling formed within.
The EASYSTEAM series is provided with stainless steel electrodes for longer duration that,
however, depends on the amount of water (level of conductivity and hardness) and work output to
which the humidifier is submitted.
When the electrodes are worn making cylinder replacement necessary, the water level rises
anomalously compared to optimal functioning, repeatedly triggering the maximum level alarm E1.
Now having checked the alarm is not caused by other anomalies (see chapter 6 Diagnostics), carry
out replacement as indicated below:
NEVER REPLACE THE CYLINDER WITH MACHINE HOT AND WITH
WATER INSIDE. BEFORE CARRYING OUT THE OPERATION, COMPLETELY
DISCHARGE THE CYLINDER USING THE MANUAL DISCHARGE KEY!
IT IS COMPULSORY TO FOLLOW THE PRESCRIPTIONS INDICATED IN
CHAPTER 7.2
1. Open the humidifier extracting the front cover as indicated in chapter 2.2. (not necessary in
OEM series models).
2. Release the front fixing spring of the upper steam flange making it slide outside the cylinder
(Fig. 27, 28, and 29).
Fig. 27 Fig. 28 Fig. 29