- 39 - Hardware Installation
Relion 2940 Chassis Manual
4-2 Jumper Setting
10
No. Jumper Code Jumper Setting
1.
CLR_CMOS
(Clearing CMOS Jumper)
1-2 Close: Normal operation (Default setting)
2-3 Close: Clear CMOS data
2.
ME_UPDATE
(ME recovery Jumper)
1-2 Close: ME recovery mode.
2-3 Close: Normal operation. (Default setting)
BIOS_PWD
3. (Clearing Supervisor
Password Jumper)
1-2 Close: Normal operation (Default setting)
2-3 Close: Clear supervisor password.
4.
BIOS_RCVR
(BIOS Recovery Jumper)
1-2 Close: Normal operation (Default setting)
2-3 Close: BIOS recovery mode.
BIOS_WP
5. (BIOS Write Protect
Jumper)
1-2 Close: Normal operation. (Default setting)
2-3 Close: Enable BIOS write protect function.
6.
ME_RCVR
(ME Recovery Jumper)
1-2 Close: Normal operation (Default setting)
2-3 Close: ME recovery mode.
7.
S3_MASK (S3 Power
On Select Jumper)
1-2 Close: Stop an initial power on when BMC is not ready.
2-3 Close: Keep initial power on. (Default setting)
BMC_FRB
8. (Force to Stop FRB
Timer Jumper)
1-2 Close: Normal operation (Default setting)
2-3 Close: Force to Stop FRB Timer.
PMBUS_SEL
9. (PMBus Power
Select Jumper)
1-2 Close: PMBus connects to PCH.
2-3 Close: PMBus connects to BMC. (Default setting)
10. ACK_SEL
(4 Nodes System
and Rack System
Switch Jumper)
1-2 Close: 4 Nodes System.
2-3 Close: Rack System.
6
5
1
7
4
8 3
9 2