Electrical
Voltage
Voltage at motor must not be more than 10% above or below motor
nameplate rated voltage or motor may overheat, causing overload
tripping and reduced component life. If voltage is less than 90% or
more than 110% of rated voltage when motor is running at full load,
consult power company.
Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or fatal
electrical shock hazard.
Do not ground to a gas supply line.
To avoid dangerous or fatal electrical shock, turn OFF
power to motor before working on electrical
connections.
Residual Current Device (RCD) tripping indicates an
electrical problem. If RCD trips and will not reset, have a
qualified electrician inspect and repair electrical system.
Exactly match supply voltage to motor nameplate
voltage. Incorrect voltage can cause fire or seriously
damage motor and voids warranty. If in doubt consult a
licensed electrician.
The pump is to be supplied by an isolating transformer
or supplied through a residual current device (RCD)
having a rated residual operating current not exceeding
30 mA.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard. Warranty is void if
unauthorised modifications are made to any component.
The MaxEPro series of pool pumps is classified as
"Double Insulated to Water Circuit". Please refer to the
Electical Wiring Rules (AS/NZS 3000) and local statutes
and regulations as to whether equipotential bonding is
necessary. Pentair Water Australia recommends
equipotential bonding for additional safety.
7