IntelliTouch i-Link Protocol Interface Adapter User’s Guide
Adapter Commands / Command Format
Adapter commands are used to set required or preferred actions and responses
for a given application. Such as the ‘RSPFMT’ command that is used to determine
the type of response expected by the computer or home automation system.
RST: Reset Adapter
Command: #RST<cr>
Response: Pentair Water - i-Link Protocol Interface Adapter v1.0
CMDCHR = #
NRMCHR = !
ERRCHR = ?
SETCHR = =
INQCHR = ?
Acquiring System Data
!READY
RSPFMT: Set/Query Command Response Format
Query: #RSPFMT ?<cr>
Response: !00 RSPFMT = x<cr>
Where x is 1 or 0.
0 indicates a verbose response (as shown).
If the RSPFMT is set to terse the response would appear as !00 x<cr>
Command: #RSPFMT = x<cr>
Response: !00 RSPFMT = x<cr>
Where x is 1 or 0.
0 indicates a verbose response (as shown).
If the RSPFMT is set to terse the response would appear as !00 x<cr>
COSMSGS: Set/Query Change Of System Messages setting
Query: #COSMSGS ?<cr>
Response: !00 COSMSGS = x<cr>
Where x is 1 or 0.
0 indicates that no Change Of System messages will be sent.
1 indicates that messages will be sent whenever a circuit state or
temperature changes.
Command: #COSMSGS = x<cr>
Response: !00 COSMSGS = x<cr> Where x is 1 or 0