IntelliTouch i-Link Protocol Interface Adapter User’s Guide
CMDCHR: Set/Query Command Character Value
Query: #CMDCHR ?<cr>
Response: !00 CMDCHR = x<cr> Where x is the character used to
prefix all Commands. By default this ‘#’
Command: #CMDCHR = x<cr>
Response: !00 CMDCHR = x<cr> Where x is the character you wish
to make the
CMDCHR. On Power up or Reset the current value is
displayed.
NRMCHR: Set/Query Normal Response Character Value
Query: #NRMCHR ?<cr>
Response: !00 NRMCHR = x<cr> Where x is the character used to
prefix all Valid (non error) responses from adapter. By
default this ‘!’
Command: #NRMCHR = x<cr>
Response: !00 NRMCHR = x<cr> Where x is the character you wish
to make the
NRMCHR. On Power up or Reset the current value is displayed.
ERRCHR: Set/Query Error Character Value
Query: #ERRCHR ?<cr>
Response: !00 ERRCHR = x<cr> Where x is the character used to
prefix all Invalid responses or error messages from
adapter. By default this ‘?’
Command: #ERRCHR = x<cr>
Response: !00 ERRCHR = x<cr> Where x is the character you wish
to make the
ERRCHR. On Power up or Reset the current value is displayed.
SETCHR: Set/Query Set Character Value
Query: #SETCHR ?<cr>
Response: !00 SETCHR = x<cr> Where x is the character used as
the operator in all Set commands.
By default this ‘=’
Command: #SETCHR = x<cr>
Response: !00 SETCHR = x<cr> Where x is the character you wish
to make the
SETCHR. On Power up or Reset the current value is displayed.
INQCHR: Set/Query Inquire Character Value
Query: #INQCHR ?<cr>
Response: !00 INQCHR = x<cr> Where x is the character used as
the operator in all Query commands. By default this ‘?’
Command: #INQCHR = x<cr>
Response: !00 INQCHR = x<cr> Where x is the character you wish
to make the INQCHR. On Power up or Reset the current
value is displayed.