What to do if Pentair ULTRATEMP shows a low water flow alarm?
- MMelinda JohnsonAug 14, 2025
If your Pentair Heat Pump displays a low water flow alarm, it means the pressure switch isn't sensing water flow. Here's what you can check: * Ensure the water circulation pump is running. * See if filters are dirty, worn, or lint traps are clogged. Clean or replace filters and inspect the pump impeller. Adjust plumbing valves and repair any suction air leaks. * Confirm that any external water bypass around the heat pump is closed. * Check the water pressure switch resistance with water flowing. If it's open, replace the switch.