Loading...
22
Installation and Users Guide
b. Then press the MENU SELECT button repeatedly until the Temperature Scale screen is displayed.
Once displayed, press the UP or DOWN arrows to toggle between the Fahrenheit and Celsius options.
The last option shown on the display will become active.
8. Temperature Offset – The control board provides the ability to increase or decrease the measured water
temperature by 2 degrees. This is setup in the Operator Setup Menu Tree as described below:
a. Press the UP and DOWN arrows simultaneously. The Language Selection screen should be displayed.
b. Then press the MENU SELECT button repeatedly until the Temperature Offset screen is displayed.
Once displayed, press the UP or DOWN arrows to select the desired offset. The last number shown
on the display will become active.
9. AutoSet Operation – The AutoSet feature periodically energizes a contactor which can be connected to
the pump to move water though the heat pump. This allows the heat pump to sense the temperature of the
body of water whose temperature is being maintained. After a temperature stabilization delay, the heat pump
will determine if it needs to start or not. If the temperature is at the desired level, the heat pump does not start
and the filter pump contactor is de-energized. If the water temperature is not at the desired level, the heat
pump starts and will run, along with the filter pump, until the water reaches the desired temperature. At that
point the filter pump and the heat pump will stop. (See AutoSet on
page 8 for further details/example.)
a. The AutoSet feature is enabled in the Main Menu Tree as follows. Press the MENU SELECT button
repeatedly until the AutoSet screen is displayed. Once displayed, press the UP or DOWN arrows to
toggle between the on and off options. The last option shown on the display will become active.
TEMPERATURE SCALE
FAHRENHEIT / CELSIUS
LANGUAGE / IDIOMA
SELECTED - ENGLISH
TEMP OFFSET
OFFSET = -2 TO +2
AUTOSET
OVERRIDE IS ON/OFF

Table of Contents

Other manuals for Pentair ULTRATEMP

Related product manuals