WCS* Read Head Position Encoding System
RS-485 Interface (LS1xx*, LS2xx*)
2020-01
19
Changing the read head address
Changing the terminator
Changing the baud rate
Base types LS*11/LS*21:
Base types LS231/LS261
Read head type
Configuration switch "S1"
Address1 2 3 4
WCS2B-LS***-0
WCS3B-LS***-0
OFF OFF X X 0
WCS2B-LS***-1
WCS3B-LS***-1
ON OFF X X 1
WCS2B-LS***-2
WCS3B-LS***-2
OFF ON X X 2
WCS2B-LS***-3
WCS3B-LS***-3
ON ON X X 3
WCS3B-LS***S-0 OFF X X X 0
WCS3B-LS***S-1 ON X X X 1
WCS2B and WCS3B
Terminator
Configuration switch "S2"
1 2
ON ON ON
OFF OFF OFF
Read head type
(* = 1 or 2)
Configuration switch "S1"
Baud rate1 2 3 4
WCS2B-LS*11
WCS3B-LS*11
X X OFF X 187.5 kBaud
WCS2B-LS*21
WCS3B-LS*21
X X ON X 62.5 kBaud
Read head type
(* = 1 or 2)
Configuration switch "S1"
Baud rate1 2 3 4
WCS2B-LS*61
WCS3B-LS*61
X X OFF X 38.4 kBaud
WCS2B-LS*31
WCS3B-LS*31
X X ON X 31.25 kBaud