406
20.01.2015 ©Velleman nv
program will display until Sunday. Once the Sunday program has been reviewed,
press the key. The display will return into running mode.
Changing a preset program
The preset program may not be suited for your family. The program may be
adjusted to suit your life style. The following instructions will allow you to change
the preset program.
Press the key to enter the program viewing mode. Press the key to select
the day of program to be modified.
Press + or - to select the hour. Press ☼ or to modify the temperature.
Example: Changing Saturday 12:00 - 16:59 CT to 12:00 - 16:59 ET.
1. Press key to enter into program viewing mode.
2. Press the + key to select the day (Saturday).
3. Press the + key until 12:00 with CT setting.
4. Press the key to change from the CT period to the ET period.
5. Repeat step 3 and 4 to change 13:00 - 14:00 from CT period to ET
period.
6. Press to confirm setting. Press to return to running mode.
7. You can check the programmed setting and confirm the setting.
Viewing and Modifying the ☼ and
Temperature
Press the key to view the CT or ET temperature mode. Press ☼ to change from
CT viewing to ET viewing and press the key to change from ET viewing to CT
viewing. The temperature is flashing at this moment. Press + or - to change CT or
ET setting. Press the key to confirm the setting and to return to the running
mode.
Setting the Temporary Manual Override Temperature
This function allows you to change the present temperature setting to a temporary
temperature setting from 1 hour up to 48 hours. Press + or - to enter the manual
override temperature mode. The temperature is flashing. Press + or – to select
the override temperature. Press to confirm the temperature setting. H1 will
be displayed and flashing. Press + or - to select the hour (max. 48 hours) Press
the key to confirm the setting.
Setting the Temporary Override Program
This function allows you to temporary modify the CT temperature to an ET
temperature setting until the next CT setting or to modify the ET temperature to a
CT temperature setting until next ET setting. The unit is running at CT program
period: Press to change ET to CT setting until next CT period. If the unit is
running at ET program hour: Press ☼ to change CT to ET setting until next ET
program.