Type | Infrared Thermometer |
---|---|
Temperature Range | -50°C to 1850°C (-58°F to 3362°F) |
Distance to Spot Ratio | 50:1 |
Response Time | 500ms |
Wavelength | 8-14μm |
Resolution | 0.1°C/°F |
Power Supply | 9V battery |
Operating Temperature | 0°C to 50°C (32°F to 122°F) |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
Display | LCD with backlight |
Auto Power Off | Yes |
Emissivity | Adjustable from 0.1 to 1.0 |
Laser Type | Class 2 |
Battery Life | Up to 12 hours |
Details the type of display used by the manometer, such as Dual LCD.
Specifies the accuracy of the manometer, typically ±0.3%FSO at 25°C.
Covers reliability (±0.2%FSO) and linearity/hysteresis (±0.29%FSO).
Indicates response time (0.5 seconds) and maximum pressure (10 psi).
Describes indicators for low battery, over range (Err.1), and under range (Err.2).
Specifies the acceptable operating (0-50°C) and storage (-1-60°C) temperature ranges.
Details power requirements (9V battery/9VDC) and standard accessories (Pouch & Tubing).
Allows selection of different measurement units for pressure readings.
Used for differential pressure measurement, subtracting a reference value.
Freezes the current displayed measurement value.
Powers the manometer on and off.
Initiates and manages the recording of measurement data (Max/Min/Avg).
Controls the illumination of the display for better visibility.
Icons indicating the Hold function and Differential mode are active.
Displays the main pressure reading, including negative values and units.
Shows the Record mode status and the Low Battery Indicator (BAT).
Indicates recorded maximum, minimum, average values and a relative time clock.
Displays the currently selected unit of pressure measurement.
Specifies the range (±55.40) and accuracy (0.01) for inH2O unit.
Specifies the range (±2.000) and accuracy (0.001) for Psi unit.
Specifies the range (±137.8) and accuracy (0.1) for Mbar unit.
Specifies the range (±13.79) and accuracy (0.01) for kPa unit.
Specifies the range (±4.072) and accuracy (0.001) for inHg unit.
Specifies the range (±103.4) and accuracy (0.1) for mmHg unit.
Specifies the range (±32.00) and accuracy (0.01) for Ozin2 unit.
Specifies the range (±4.612) and accuracy (0.001) for ftH2O unit.
Specifies the range (±140.6) and accuracy (0.1) for cmH2O unit.
Specifies the range (±0.140) and accuracy (0.001) for Kgcm2 unit.
Specifies the range (±0.137) and accuracy (0.001) for Bar unit.
Instructions for turning the manometer on and off.
How to clear displayed data, both automatically and manually.
Guidance on using the UNITS button to change measurement units.
Explanation of how the DIF button calculates differential pressure.
How to use the HOLD button to freeze and exit the hold function.
Using the REC button to record and stop Max/Min/Avg measurements.
How to turn the display backlight on and off.
Details on the auto power-off feature and how to disable it.
Explains error messages like Err.1 (over range) and Err.2 (under range).
Information on the low battery indicator (BAT) and replacing the 9V battery.
Instruction to stop using the product immediately if it operates abnormally.
Emphasizes testing the manometer before use to ensure proper operation.
Ensuring connecting hoses are free from kinks, blockages, or splits.
Steps to take if gas leakage is suspected: turn off supply, ventilate, find source.
Warning against disassembling or modifying the manometer to prevent accidents.