Problem – Button on PerfectPass Display does not work.
Check - If system was just installed, unplug Display from harness and inspect all
brass pins on connector to ensure they are inline. If problem occurs after much
use, the Display will require repairs by PerfectPass.
Problem – In Wakeboard/Trick mode, system sluggish or exhibits some
surging.
Check – Inspect paddle wheel. If paddle appears OK, go into adjustable
parameters by highlighting menu arrow icon, press UP and Wakeboard will
appear. Press DOWN for settings.
KDW will appear. This value represents how firm the system will control. Heavily
loaded boats may need higher settings. (Typical values 80 – 200)Press Menu to
proceed.
NNW will appear. This is the filter factor of paddle. The higher the value, the
more filtering is done prior to making a speed change.(Typical values 80 – 180)
Problem – The boat accelerates past set speed too far in Wakeboard Mode
before settling in.
Check – Go to “Control Settings” and lower the “CS” value.
Control Settings CR / CS)
These are engagement values which are adjustable to allow a customer to fine
tune engagement performance if necessary. This may be required due to a prop
change, unusual ballast loads or operating at extreme elevations.
These are found under “CTRL SETTNGS” in sub menu by pressing Menu & Up
Keys together.
CS – Control the engagement in paddle wheel speed based modes including
wakeboard.
If it is set too low, the system may not go fast enough to engage, or it will engage
& then disengage. If it is set too high, it may overshoot the set speed by several
mph before beeping and taking over. Factory setting is 750. (Range is 735 – 900)
CR – Is the same as CS except it controls engagement of the RPM Based
Modes such as slalom. Factory setting is 1940. (Range is 1900 – 2100) It would
be rare to see this value require adjustment.
Software Adjustments
System Reset – To reset the entire system back to original factory values, press
& hold ON/OFF & MENU Keys together as you turn key on to power
PerfectPass. Continue holding for a few seconds until [ System Reset ^ = Yes ]
appears. Then simply answer questions as they appear.
PerfectPass Control Systems (902) 468-2150 Page 6