Do you have a question about the Performance Tool W2275 and is the answer not in the manual?
Owner's responsibility to study warnings, instructions, and maintain decals/unit.
Observe safety information to protect self and others; understand instructions.
Check amperages of plugged-in tools/appliances against reel's maximum ratings.
Handle reel with dry hands, use GFCI, inspect before use, wear safety gear, follow codes.
Unplug before installing, follow instructions, wear safety gear, keep area clean and clear.
Select location near outlet, attach hook to joist, hang reel securely, test stability.
Plug into outlet, pull cord to desired length, retract cord slowly, avoid full extension pull.
Unplug before maintenance. Clean with damp cloth and mild soap; avoid solvents.
The 20 FT Retractable Cord Reel, Stock Number W2275, is a practical and convenient solution for managing electrical cords in various settings, particularly in garages, workshops, or other areas where a flexible and easily stored power source is needed. This device is designed to provide a readily accessible extension cord while minimizing clutter and the tripping hazards associated with loose cables. Its retractable mechanism ensures that the cord is neatly stored when not in use, and can be extended to the desired length for operation.
The primary function of this cord reel is to supply electrical power through an integrated extension cord, which can be extended and retracted as needed. It serves as a general indoor power source, allowing users to connect tools and appliances that require a 110-125V, 60Hz power supply. The reel's design incorporates a spring-loaded mechanism that automatically rewinds the cord when a slight pull is applied past a certain point, ensuring a tidy workspace. When pulling the cord out, a clicking noise indicates that the cord is locking into place at the desired length, preventing it from retracting prematurely. This feature provides flexibility, allowing users to work at various distances from the power outlet without excess cord lying on the ground. The cord reel is equipped with a 3-prong grounded plug, which is essential for reducing the risk of electrical shock when connected to a properly grounded 3-prong outlet. It is crucial to never modify this plug or use adapter plugs, as this compromises safety. The device is not waterproof and is specifically intended for indoor use, away from wet locations such as showers, sinks, or tubs. This limitation is a critical safety consideration to prevent electrocution.
The cord reel is designed for ease of use and convenience. Installation involves selecting a suitable location within two feet of an electrical outlet, preferably near a ceiling joist for secure mounting. It is important to note that drywall alone will not support the weight of the reel assembly, necessitating attachment to a structural element like a ceiling joist using a hook, clip, or other secure locking device. Once securely mounted and plugged into a polarized outlet, the cord can be pulled out to the desired length. The clicking sound confirms that the cord is locked in position. To retract the cord, a gentle pull past the locking point will initiate the rewind process, and the user should guide the cord slowly back into the reel to prevent damage or injury from excessive rewind speed. An adjustable rubber stop on the cord allows users to set the extended length, preventing the cord from retracting too far into the reel when not in use. This feature is particularly useful for maintaining a consistent working length.
Safety is paramount when using this cord reel. Users must always inspect the device before each use for any loose or damaged parts or worn insulation. Wearing ANSI-approved safety goggles and heavy-duty work gloves during use is recommended. It is imperative to adhere to all electrical and safety codes, including the National Electric Code (NEC) and OSHA regulations. The power source must always conform to the requirements specified on the cord reel. Disconnecting the power before any servicing or inspection is a critical safety measure. The cord reel is not intended for use in potentially dangerous locations, such as flammable or explosive atmospheres. Users should avoid body contact with grounded surfaces like pipes, radiators, ranges, and refrigerators, as this increases the risk of electric shock if the body is grounded. The cord reel should be kept away from heating vents, radiators, or other sources of heat. It is also important to keep the cord reel out of reach of children. The device is designed for general indoor power source applications and should only be used as intended. Overloading the cord reel by plugging in tools or appliances with amperages exceeding the maximum rating can lead to serious injury, electrical shock, or fire. Therefore, users must always check the amperage ratings of their tools and appliances to ensure they do not exceed the cord reel's capacity.
Proper maintenance is essential to ensure the longevity and safe operation of the cord reel. Users are advised to remove dirt and grime as soon as it accumulates. Cleaning should be done using a soft, damp cloth and a mild soap. It is crucial to avoid getting the electrical plug wet and never submerge any part of the cord reel in any cleaning solution. Solvents such as gasoline or turpentine should not be used for cleaning, as they can damage the unit. To maintain smooth retraction, the reel cord itself should be kept clean. This can be achieved by pulling the cord to its full length and allowing it to retract through a dampened rag. For a more thorough cleaning, the process can be repeated with a clean rag sprinkled with talcum powder. After any cleaning, the cord reel must be thoroughly dried before being plugged back into an outlet. Regular inspection of the cord reel for any signs of wear, damage, or loose parts is also a critical maintenance practice. Maintaining all decals and warning labels in good condition is important, as they provide vital safety information. If any part of the cord reel becomes damaged or worn, it should not be used until repaired or replaced. The owner/operator is responsible for ensuring the unit is in good working order and that all safety instructions are understood and followed.
| Type | Angle Grinder |
|---|---|
| Voltage | 120V |
| No Load Speed | 11, 000 RPM |
| Spindle Thread | 5/8"-11 UNC |
| Wheel Diameter | 4-1/2" |
| Arbor Size | 7/8" |
| Amperage | 7.5A |