i02593769
Features and Controls
Fuel Shutoff
The fuel shutoff solenoid is located on the fuel
injection pump. When the fuel shutoff solenoid is
activated, the solenoid moves the fuel rack to the
OFF position.
Illustration 32 g01305771
(1) Fuel shutoff solenoid
If an electronically controlled governor has been
installed the governor operates the fuel rack in order
to stop the engine.
SEBU8311-09
31
Operation Section
Features and Controls

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Perkins 404D-22 and is the answer not in the manual?

Perkins 404D-22 Specifications

General IconGeneral
Number of Cylinders4
AspirationNaturally Aspirated
Bore84 mm
Stroke100 mm
Fuel SystemDirect Injection
Engine Model404D-22
Engine TypeDiesel
Compression Ratio23.3:1
Cooling SystemLiquid
Displacement2.2 liters
Emissions ComplianceEU Stage IIIA