Additions of SCA are based on the results of the test.
The size of the cooling system determines the
amount of SCA that is needed.
Use the equation that is in Table 16 to determine the
amount of SCA that is required, if necessary:
Table 16
Equation For Adding The SCA To The Heavy-Duty Coolant For
Maintenance
V × 0.014 = X
V is the total volume of the cooling system.
X is the amount of SCA that is required.
Table 17 is an example for using the equation that is
in Table 16 .
Table 17
Example Of The Equation For Adding The SCA To The Heavy-
Duty Coolant For Maintenance
Total Volume of the
Cooling System (V)
Multiplication
Factor
Amount of SCA
that is Required (X)
15 L (4 US gal) × 0.014 0.2 L (7 oz)
Cleaning the System of Heavy-Duty
Antifreeze
Clean the cooling system after used coolant is
drained or before the cooling system is filled with
new coolant.
Clean the cooling system whenever the coolant is
contaminated or whenever the coolant is foaming.
SEBU8726 79
Refill Capacities
Fluid Recommendations

Table of Contents

Other manuals for Perkins 854E-E34TA

Related product manuals