TDP072d+e.doc Rev.07.07.2015 Seite‐Page54/64
PerrotREGNERBAUCALWGmbHIndustriestraße19‐29/D‐75382Althengstett/Germany
Telefon:0049‐7051‐162‐0/Fax:0049‐7051‐162–133
E‐mail:perrot@perrot.de/E‐mailKonstruktion:technik@perrot.de
Note: Ifthedesignatedtimeofastationisexceeded,thefailurewillbeloggedinthe
„sensorposition“menu(seenextfigure).
Thenumbershowninthecenterofthesensorpositionbarequalsthenumberoffailuresofthe
individualstation.Todeletethefailurelog,pleasecalibratethisstation.
Cycletime
Thetimeenteredinthismenuisonlyusedtocalculatetheruntimeofanirrigationprogram.Due
tothefactthatthenumberofsectorrunsisenteredinthecontrollerinsteadofacertaintime,the
controllerwillcalculatetheruntimeasfollows:
Runtime=numberofsectorrunsxcycletime
Pleasesetcycletimeasfollows:
Use and toselect„cycletime“
Use or toincrease/decreasetheselecteddigit
Adjustmentrange: 60–180seconds
Factorysetting: 120seconds
Note: Atmax.rotationspeedtheVP3sprinklerneedsabout70secondsforasector
of180°.Thesectortimeshouldbeatleast50%longersothatthecalculated
runtimeisdefinitelylongerthantheactualruntimeinordertoavoid
overlappingstarttimes.