EasyManuals Logo

Perun V2 Hybrid User Manual

Perun V2 Hybrid
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
10
Problem and LED color
Description
Main transistor or driver
damage
Red and yellow blinking
alternately
The main transistor or driver is damaged. The unit needs to be sent
back for repair.
Battery voltage sensing
malfunction
Red and white blinking
alternately
The battery detection system is malfunctioning. The unit needs to be
sent back for repair.
Other known problems:
Cause
Solution
Motor and battery are too strong
for the main spring, which causes
an overspin.
Enable AB or precocking.
Too high precocking level
Set precocking to a lower level.
Trigger mechanism malfunction.
Check the cut-off lever and contacts, replace
if needed.
Incompatible T-Deans battery
connector.
T-deans plugs and sockets from various
manufacturers may sometimes not work
together reliably. Although the plug may
seem to fit the socket nicely, the conductive
surfaces may not contact each other, cutting
the power off. In that case try with another
battery, most preferably with a T-deans
socket made by different manufacturer.
The battery has too low capacity
(mAh) and/or “C” parameter.
Use a battery with higher capacity and/or
“C” parameter.
The motor is too weak.
Use a stronger motor, possibly with
neodymium magnets.
Increased motor load caused by an
excessive friction, for example
caused by:
- improper shimming,
- motor positioned askew in the
pistol grip.
Remove the cause of the friction.
The motor/gear ratio/spring
combination draws too much
current (for instance high speed
motor, high speed gears and M120
spring).
Change the replica configuration by using a
softer spring, gears with higher ratio (lower
speed, higher torque) or motor with higher
TPA number (or lower revolution speed).
A gearbox jam or a short-circuit is
present but because of low battery
power or bad connection with the
battery, the unit resets due to
voltage drop instead of the
electronic fuse properly activating.
Remove the reason of the gearbox jam or
short-circuit.
The build is too power demanding
for the battery use and the unit
resets due to voltage drop.
Use a higher-powered battery.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Perun V2 Hybrid and is the answer not in the manual?

Perun V2 Hybrid Specifications

General IconGeneral
Adjustable trigger sensitivityYes
Li-Po/Li-Ion/Li-Fe readyYes
Short-circuit protectionYes
Overheat protectionYes
TypeElectronic
MOSFET typeN-channel
Active brakeYes
PrecockingYes
ROF controlYes