4 5
Model
System Capacity Grains Flow Rate
Regeneration
Water Usage
Factory Setting
(Gallons)
Mineral
Tank Size
Resin
Cu. Ft.
Brine Tank / Cabinet Size
Inches
Salt Capacity
(Lbs)
Ship Weight
(Lbs)
@ 10 Lbs/Cu ft
@ 6 Lbs/Cu Ft
(Factory Setting)
@ 3 Lbs/Cu Ft
Service
USGPM
Backwash
USGPM
PW75V-75
21,000 18,750 11,550 8.0 1.5
56.7
8 x 44 0.75
BTS 15.0x34.7/BTR 18.1x34.7 BTS 230 /BTR 270
93
PW75V-100
28,000 25,000 15,400 10.0 2.0
67.2
9 x 48 1.00
BTS 15.0x34.7/BTR 18.1x34.7 BTS 230 /BTR 270
110
PW75V-150
42,000 37,500 23,100 12.0 2.4
76.2
10 x 54 1.50
BTS 15.0x34.7/BTR 18.1x34.7 BTS 230 /BTR 270
141
PW75V-200
56,000 50,000 30,800 15.0 3.5
124.4
12 x 52 2.00
20.3 x 37.4
385 158
PW75V-250
70,000 62,500 38,500 15.0 4.0
135.4
13 X 54 2.50
20.3 x 37.4
385 198
PW75V-300
84,000 75,000 46,200 15.0 5.0
173.2
14 x 65 3.00
23.0 x 40.5
550 244
PW75V-75C
21,000 18,750 11,550 8.0 2.0
66.7
9 x 35 0.75
13.8 x 23.6 x 43.3
225 93
PW75V-100C
28,000 25,000 15,400 10.0 2.4
75.2
10 x 35 1.00
13.8 x 23.6 x 43.3
225 110
SPECIFICATIONS
Working Temperature: This unit must be
operated at temperatures between 40°F and
110°F (4°C - 43°C).
Working Pressure: This water softener
must be operated on pressures
between 30 psi to 125 psi. If the water
pressure is higher than 125 PSI, use a
pressure reducing valve in the water supply
line to the softener.
Voltage = 120V / 60 Hz
Pipe Size = 3/4” and 1”
• At the stated service flow rates, the
pressure drop through these devices will
not exceed 15 psig.
• The manufacturer reserves the right
to make product improvements which
may deviate from the specifications
and descriptions stated herein, without
obligation to change previously
manufactured products or to note the
change.
* Do not use water that is microbiologically
unsafe without adequate disinfection
before or after the system.
Peak flow rates intended for intermittent
use only (10 minutes or less) and are for
residential applications only. Do not use
peak flow rate for commercial applications
or for a continuous rate when treated
water supplies are geothermal heat pump,
swimming pool, etc.
For satisfactory operation, the pumping rate
of the well system must equal or exceed
indicated backwash flow rate.
All units come with plastic bypass
Maximum Iron = 1.5 ppm
Maximum Hydrogen Sulde = 0.0 ppm
Maximum Manganese = .75 ppm
pH = 6.5 to 8.5