TBM
Page 14 V1.1 - May 2010
9. TECHNICAL DATA
TBM Resolution
Measuring range voltage service-battery 8,5-30 V DC (0,01 V)
Measuring range I (current) 0-600 A (0,01A)
Measuring range Amphours 0-6000 Ah (1 Ah)
Measuring range starter / bowbattery 0-32 V DC (0,1 V)
Measuring range remaining time 0-99,9 h (6 min)
Power supply (through shunt) 8,5-30 V DC
Power consumption 3,5mA during operation, 55mA with illumination (for 12V-plants)
Tank sensor resistance sensor 10 - 180 Ohm
SHA 150 / SHA 300 / SHA 600, active Shunt 150 A /60 mV, 300 A /60 mV or 600 A/60 mV
Accuracy voltage: ± 0,6% ± 1 digit
Accuracy current: ± 0,8% ± 1 digit