EasyManua.ls Logo

Philips 32PFL4507/F7 - Power Supply CBA Bottom View

Philips 32PFL4507/F7
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-22
1
23
GND
J124
GND
J125
Q656
J126
P-ON+21V
GND
J128
J129
GND
GND
J130
R601
VCC
J131
R602
GND
J132
R606
R607
R608
R611
R612
R613
CN601
L1001
FH601
C601
FH602
C602
C603
C604
C605
C606
CN631
1
2
23
C614
R650
C615
C616
D402B
C617
R654
R655
R657
R670
R671
R678
D657B
C650
C650
C651
C652
C653
C654
D401
C655
C656
D405
D406
D601
D602
C662
D603
C663
D604
D607
D608
D609
D610
IC601
T601
1
6
CN1001
7
2
C1001
C1007
C1010
C1011
BC1002
D1005B
D650
D651
GND
J605
D652
GND
J606
D653
GND
J607
D654
GND
J608
GND
J609
D658
R501
D1002
R1003
D660
D662
D663
D661B
JS631
P-ON+21V
for Z-SoC
JS632
ALL+3.3V forR-SoC
ALL+5.3V forP-SoC
D605B
Q601
Q602
L601
L602
BC601
BC602
BC603
BC604
GND
J101
P-ON-H2
J102
P-ON-H2+
J103
RESET
J104
GND
J105
GND
J106
P-ON+21V
J107
ALL+5V-CONT.
J108
GND
J109
PROTECT1
J110
GND
J111
GND
J112
P-ON+21V
J113
GND
J114
GND
J115
PROTECT1
J116
ALL+5-CONT.
J117
P-ON-H2+
J118
PROTECT3
J119
PROTECT3
J120
BL-ADJ
J121
GND
J122
GND
J123
BA21F0F0102 2
4A/125V
F601
GT601
GT602
JS601
JS602
R672
J133
GND
J127
J134
GND
P-ON+21V
A
BC
D
E
SA602
SA603
SA601
1.GND
2.BL-SW
3.BL-ADJ
4.P3
5.P1
6.GND
7.P-ON-H2
8.RESET
9.GND
10.GND
11.ALL+3.3V
/ALL+5.3V
12.GND
13.AMP+24V
14.AMP+24V
15.GND
16.17.21V
18.19.20.21.GND
22.23.21V
7.ILED2
6.ILED1
5.NC
4.VLED
3.NC
2.ILED3
1.ILED4
Q654
R401
Q655
R402
R403
D610A
R603
R604
R605
R610
R614
R650A
R1501
R1502
R1503
R1504
R612A
R670A
R613A
R671A
D652A
D401A
C607
C608
R672A
C609
C610
R651
R652
R653
D654A
R658
R654A
R659
R660
R661
R662
R663
R664
R665
R666
R667
R668
R655A
R669
C630
C631
C632
C633
C635
C636
R673
C637
C638
R675
C639
R676
R677
R680
D405A
R681
R682
R657A
D406A
D402
C658
C659
Q501
D658A
C660
C661
C664
D605
C665
R678A
C1002
C1003
C1004
Q1001
C1005
C1006
C1014
C1015
C1016
C1017
C1018
C1019
C1020
D657
D1001
R502
D1004
D1005
R1001
R1002
R1004R1005
D661
R1006
R1007
R1008
IC1001
R1009
R1010
R1011
R1012
R1014
R1015
R1016
R1017
R1018
R1019
D102A
C501
D663A
R606A
D607A
R607A
D608A
R608A
D609A
D501
D502
Q650
Q652
Q653
R1021
R1020
C1021
C1022
D656
C1008
C1009
C1012
C1013
1
12
13
24
Power Supply CBA Bottom View
BA21F0F01022
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 4A, 125V fuse.
CAUTION ! :
ATTENTION : Utiliser un fusible de rechange de même type de 4A, 125V.
4A 125V

Table of Contents

Other manuals for Philips 32PFL4507/F7

Related product manuals