EasyManua.ls Logo

Philips Senseo Switch - Repair: Pump and Intensity Calibration; Manual Pump Adjustment Steps; Intensity Select Calibration Process

Philips Senseo Switch
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HD6596/50/G /51/G
8-18
Manual pump adjustment
1. Keep the 1-cup and 2-cup button pressed while connecting the appliance to the mains.
2. The buttons can be released when the 1-cup and 2-cup LEDs are switched on.
You entered automatically the 1-cup pump time adjusting step.
3. 1-cup adjustment:
a. Press and release the 1-cup button to decrease the calibration value.
The 1-cup and 2-cup LEDs blink one time.
b. Press and release the 2-cup button to increase the calibration value.
The 1-cup and 2-cup LEDs blink one time.
4. Store new 1-cup pump time values:
Press and release the 1-cup and 2-cup buttons to store the calibration value.
The 1-cup and 2-cup LEDs blink rapidly 3 times.
You enter automatically the 2-cup pump time adjusting step, 1-cup and 2-cup buttons are on.
5. 2-cup adjustment:
a. Press and release the 1-cup button to decrease the calibration value.
The 1-cup and 2-cup LEDs blink one time.
b. Press and release the 2-cup button to increase the calibration value.
The 1-cup and 2-cup LEDs blink one time.
6. Store new 2-cup values:
Press and release the 1-cup and 2-cup buttons to store the calibration value.
The 1-cup and 2-cup LEDs blink rapidly 3 times.
Intensity select (scale factor calibration)
Depending if the “intensity select” feature is enabled or disabled the 1-cup or 2-cup LED is switched on.
See table below:
Intensity select disabled
(HD7892 & HD6591)
1-cup LED is on 2-cup LED is o
Intensity select enabled
(HD6592 & HD6596)
1-cup LED is o 2-cup LED is on
7. Check/press the desired button following the above table for the desired state.
8. Press and release the 1-cup and 2-cup button at the same time to store the value, the 1-cup and 2-cup LEDs blink
rapidly 3 times.
9. If the “Intensity selection” is disabled (1-cup LED) has being selected in step 6, LED’s will switch o .
go to step 12.
10. If the “Intensity selection” is enabled (2-cup LED) has being selected the scale factor for the 60 ml setting need to be
checked/adjusted.
Adjusting the scale factor for the strong/short cup volume (both cups).
11. Depending if the volume has to de- or increase you have to push the one- or two-cup button.
Every time you push the 1- or 2-cup button, the LED will turn o for 0.5 second (feedback to user) and the scale factor
will be shortened or lengthened depending which button was pushed.
Pushing 1-cup button, scale factor will be shorten approximately - 1 cc/ml (less co ee)
Pushing 2-cup button, scale factor will be lengthen approximately + 1 cc/ml (more co ee)
The new value will be stored when you press and release the 1-cup and 2-cup button at the same time, the 1-cup and
2-cup LEDs blink rapidly 3 times.
12. Turn appliance on again and brew one normal co ee and check according speci cation.
13. Brew one strong co ee cup by pressing the 1-cup button twice, measure the volume.
14. In case the volume is not within speci cation repeat steps 1 – 11.
15. End of procedure.
Repair instruction

Related product manuals