Mechanical Instructions
EN 15LCD AUO 2k8 4.
4.8 Model T420HW01V4
4.8.1 Control Board
Disassembly
1. Place the panel face down on the foam bars, and locate the
Control board.
Figure 4-37 Control board location
2. Remove the four screws of the metal cover: start with the
right-down one, then the left-up, one, then the right-up one
and finally the left-down one.
Figure 4-38 Cover screws removal
3. Carefully disconnect the flat cable/FPCs from their
connectors.
Figure 4-39 Unplug FPCs
4. You now can remove the Control Board.
Reassembly
To reassemble, perform all processes in reverse order.
Important: Be sure to insert the FPCs correctly: the black (or
sometimes white) line must follow the edge of the connector
(see figure below).
Figure 4-40 Correct FPC insertion
4.8.2 Inverter Board
These displays have the Inverter Board located on the PSU.
This is a so-called IPB (Integrated Power Board).
I_17791_016.eps
020408
I_17791_017.eps
020408
I_17791_018.eps
020408
I_17791_019.eps
020408