8
Mechanical Instructions
V40 107P5
0. General
2. Video panel
3.Main board connector in Fig. 4
To be able to perform measurements and repairs on the "circuit
boards", these unit should placed in the service position first.
-Remove 2 screws as shown
-Remove back cover as shown
-Remove pedestal as shown
-Remove cover clip at right and left side on the back cover in Fig2.
-Disconnect york wire
-Disconnect rotation connector
-Disconnect control board connector
-Remove Screw for fixed I/F cable
1.Remove the rear cover in Fig. 1.
- Disconnect the wire between metal shield of Video panel and
CRT neck as shown in Fig. 3.
- Disconnect the CRT ground from Video panel.
- Remove screw grounding and grounding wire in Fig. 3.
Fig. 1
Screw
Screw
Pedestal ass'y
Video Panel
CRT grouding wirel
Fig. 3
Clip
Fig. 2
Fig. 4
Cover clip
Control connector
Signal connector
Degaussing wire connector
Rotation connector
http://jdwxzlw.5d6d.com/?fromuser=华盛维修