USER MANUAL – Arrow QG™/VI™
© 2022 Phillips Connect LLC Arrow QG/VI User Manual Page 4 of 10
UART
A UART port is provided for AT command and data interaction and optionally for application
specific control.
Relay Driver
A 500mA sink capable output pin is provided. This pin is meant to drive a relay coil intended to
interrupt the starter solenoid relay for the ignition circuit to a car, tractor, or other vehicle.
Voltage Monitor
The battery monitor is internal analog input scaled such that the DC value of the power input pin
to the power input pin to the Arrow QG (Arrow VI) system is measured.
Watchdog
MDM9207-1 chipset provides internal software and hardware Watchdog.
Motion Detect
This function will work with firmware power down options to keep the Arrow QG (Arrow VI) in a
very low power down state until motion is detected. Upon wakening, a report can then be
generated.
CAN
This function is an option for watching the information of vehicle.
2.2 BASIC RF PERFORMANCE