PHNIX
Swimming Pool Heat Pump
Technical Manual
PHNIX reserves the right to discontinue, or change at any time, specifications or designs
without notices and without incurring obligations.

Questions and Answers

  • M
    michaelpowellAug 15, 2025
    What to do if PHNIX Water Pump has communication failure?
    • S
      Steven KellyAug 15, 2025
      If your PHNIX Water Pump experiences communication failure between the wire controller and the main board, the likely cause is a connection issue. You should check the connection between the wire controller and the main board to resolve this.
  • M
    Michael JohnsonAug 18, 2025
    What to do if PHNIX PASRW035 shows high pressure protection?
    • D
      dawsoncharlesAug 18, 2025
      If the PHNIX Water Pump triggers high pressure protection (HP), the HP switch might be broken. To resolve this, check or change the HP switch.
  • J
    Jason CantrellAug 21, 2025
    What to do if PHNIX PASRW035 Water Pump shows low pressure protection?
    • B
      Bethany MyersAug 21, 2025
      If the PHNIX Water Pump triggers low pressure protection (LP), it might be due to a broken LP switch. You should check or change the LP switch.
  • A
    Austin RoseAug 25, 2025
    Why does my PHNIX Water Pump have antifreezing protection?
    • K
      Kyle HardingAug 25, 2025
      If the PHNIX Water Pump activates antifreezing protection, it's likely because the antifreezing temperature is below 2 degrees. In this case, check the flow and water system.
  • C
    courtneysolomonAug 27, 2025
    What causes water flow protection in PHNIX PASRW035 Water Pump?
    • M
      Mr. Jason HarrisAug 27, 2025
      If your PHNIX Water Pump indicates a water flow protection issue, the flow switch may be broken. You should check or change it.
  • L
    Leonard AcostaAug 30, 2025
    How to fix water inlet temp sensor failure in PHNIX Water Pump?
    • K
      Karen JohnsonAug 30, 2025
      If the PHNIX Water Pump reports a water inlet temperature sensor failure, the temperature sensor is likely broken. You should check or change it.
  • A
    Aaron TerrySep 2, 2025
    How to fix water outlet temp sensor failure in PHNIX PASRW035?
    • S
      Steven StevensSep 2, 2025
      If the PHNIX Water Pump indicates a water outlet temperature sensor failure, the temperature sensor is probably broken. You should check or change it.
  • D
    davishelenSep 5, 2025
    How to fix ambient temp sensor failure in PHNIX PASRW035 Water Pump?
    • L
      Lauren JohnsonSep 5, 2025
      If the PHNIX Water Pump shows an ambient temperature sensor failure, the temperature sensor is likely broken. You should check or change it.
  • J
    Jackie LopezSep 8, 2025
    How to fix coil temp sensor failure in PHNIX PASRW035 Water Pump?
    • J
      Julie CoxSep 8, 2025
      If your PHNIX Water Pump displays a coil temperature sensor failure, the temperature sensor is likely broken. You should check or change it.
  • P
    Patrick PachecoSep 12, 2025
    How to fix suction temp sensor 1 failure in PHNIX PASRW035 Water Pump?
    • S
      Savannah NewtonSep 12, 2025
      If your PHNIX Water Pump indicates a suction temperature sensor 1 failure, the temperature sensor is likely broken. You should check or change it.

Summary

Summary of Product

Preface

Introduction to the manual and its purpose for PHNIX swimming pool heat pumps.

Product Presentation

Overview of the PHNIX swimming pool heat pump's features and benefits.

Nomenclature

Explains the model naming convention and its components.

Operating Principle

Details the heat transfer mechanism and working principle of the heat pump.

Key Features

Highlights the main advantages and design aspects of the heat pump unit.

Performance and Specification

Technical Specifications

Provides detailed performance data, dimensions, and electrical requirements for various models.

Performance Curves

Illustrates the heat pump's performance across different ambient and water temperatures.

Installation Guide

Installation Notice and Safety

Details crucial safety warnings, cautions, and mandatory installation practices.

Unit Handling and Preparation

Covers deposition, transportation, inspection, handling, and unpacking procedures.

Installation Site Requirements

Provides guidance on installation location, prerequisites, and necessary space.

Hydraulic System Connection

Explains the hydraulic system connection process using PVC pipes and fittings.

Electrical Wiring Guide

Details the procedures and diagrams for connecting the unit's electrical wiring.

Trial Running and Thermal Insulation

Outlines the trial running process and suggests thermal insulation for efficiency.

PC1001 Controller Operations

Controller Panel and Operation

Explains the controller's buttons, operation, and panel layout for basic control.

Display Explanation and Modes

Details display symbols, indicators, and how to select different operation modes.

Temperature and Parameter Settings

Guides on setting target temperatures and configuring user/factory parameters.

Advanced Controller Functions

Covers keyboard lock/unlock, clock settings, and timer functions.

Download Operation

Explains the procedure for uploading or downloading unit settings and parameters.

PCB I;O Ports and Troubleshooting

Describes PCB connections and lists common malfunctions with their reasons and solutions.

Detailed Parameter Table

Provides a comprehensive list of adjustable parameters, their codes, settings, and descriptions.

Appendix: NTC R-T Table

NTC R-T Table for Temperature Sensors

Reference table correlating NTC resistance values with temperatures for sensor diagnostics.

PHNIX PASRW035 Specifications

General IconGeneral
ModelPASRW035
CategoryWater Pump
Rated Voltage220-240V
Rated Frequency50Hz
Rated Power35W
Inlet/Outlet Diameter25mm
Noise Level45dB
Max Flow Rate35L/min