RAD-...-IFS
32 / 198
PHOENIX CONTACT 105542_en_05
RS-485 front module
The RAD-RS485-IFS RS-485 front module for I/O extension modules allows Radioline sta-
tions to be operated via a 2-wire RS-485 bus system. The front module can be extended
with up to 32 I/O extension modules via the DIN rail connector.
You can connect Radioline RS-485 stations to a Radioline master wireless module and
thereby extend the wireless network. All devices in the wireless network and in the RS-485
network form one system. All stations are addressed uniquely using the yellow thumbwheel.
The I/O signals can be distributed easily between all the stations, regardless of the medium
used.
Figure 4-2 I/O-to-I/O, wireless, and RS-485
The RAD-RS485-IFS RS-485 front module is not described in this user manual.
For additional information, visit phoenixcontact.com/product/2702184
.
RS-485 RS-485 RS-485
RS-485
RAD-2400-IF
S
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
0
1
SET
D(A)
D(B)
RX
COM
1
TX
NO
2
GND
NC
1
+24V
RSSI
+
0V
ANT
RSSI
-
RAD-D
AIO6-IFS
IO-MAP
OFF ON
DIP-1
1
2
3
4
PWR
DAT
ERR
DO4
DO3
DO2
DO1
DI1L
DI2L
DI1H
DI2H
DI1
DI2
UL1 +I1 -I1
U1 I1
1
COM1
COM2
NO1
NO2
NC1
NC2
1 2
RAD-DOR4-IF
S
8 8
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
2 2
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3
RAD-DI4-IF
S
DI1L
DI2L
DI1H
DI2H
DI1
DI2
PWR
DAT
ERR
DI4
DI3
DI2
DI1
DI3L
DI4L
DI3H
DI4H
DI3
DI4
7 7
IO-MAP
RAD-2400-IF
S
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
0
3
SET
D(A)
D(B)
RX
COM
1
TX
NO
2
GND
NC
1
+24V
RSSI
+
0V
ANT
RSSI
-
RAD-DOR4-IF
S
8 8
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
2 2
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3
RAD-2400-IF
S
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
0
4
SET
D(A)
D(B)
RX
COM
1
TX
NO
2
GND
NC
1
+24V
RSSI
+
0V
ANT
RSSI
-
RAD-DI4-IFS
DI1L
DI2L
DI1H
DI2H
DI1
DI2
PWR
DAT
ERR
DI4
DI3
DI2
DI1
DI3L
DI4L
DI3H
DI4H
DI3
DI4
8 8
IO-MAP
RAD-AI4-IFS
PWR
DAT
ERR
2 2
IO-MAP
OFF ON
DIP-1
1
2
3
4
Pwr1
Pwr2
+I1
+I2
-I1
-I2
Pwr3
Pwr4
+I3
+I4
-I3
-I4
RAD-2400-IF
S
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
0
2
SET
D(A)
D(B)
RX
COM
1
TX
NO
2
GND
NC
1
+24V
RSSI
+
0V
ANT
RSSI
-
RAD-DOR4-IF
S
8 8
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-DAIO6-IFS
IO-MAP
OFF ON
DIP-1
1
2
3
4
PWR
DAT
ERR
DO4
DO3
DO2
DO1
DI1L
DI2L
DI1H
DI2H
DI1
DI2
UL1 +I1 -I1
U1 I1
1
COM1
COM2
NO1
NO2
NC1
NC2
1 2
RAD-RS485-IFS
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
LINK
0
5
SET
D(A)
D(B)
COM
1
NO1
NC1
+24V
0V
RAD-DOR4-IF
S
7 7
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
4 4
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3
RAD-RS485-IFS
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
LINK
0
6
SET
D(A)
D(B)
COM
1
NO1
NC1
+24V
0V
RAD-DOR4-IF
S
7 7
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
4 4
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3
RAD-RS485-IFS
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
LINK
0
7
SET
D(A)
D(B)
COM
1
NO1
NC1
+24V
0V
RAD-DOR4-IF
S
7 7
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
4 4
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3