• Arming with zone partialisation:
ATTENTION: For arming with zone partialisation, refer exclusively to the beeps of the internal buzzer.
This function allows the alarm to be activated by excluding certain areas of the vehicle. It can be useful if it is necessary to leave animals or
people on board or the windows open, while maintaining the remaining (perimeter) protection.
Alarm partialisation is carried out using the remote control supplied, by pressing the "S" button: each time it is pressed, the buzzer will
respond with a certain number of beeps according to the following logic:
Beep when the alarm is armed:
1 beep: ZONE 1 = OFF; ZONE 2 = ON; ZONE 3 = ON
2 beep: ZONE 1 = OFF; ZONE 2 = OFF; ZONE 3 = ON
3 beep: ZONE 1 = ON; ZONE 2 = ON; ZONE 3 = OFF
4 beep: ALL ZONES ACTIVE
After 4 beeps, the next press of the "S" button will restart the cycle from the beginning.
Beep when alarm is disarmed:
1 long beep: ALL ZONES OFF
- Pressing the close button on the original remote control or on the one supplied will completely arm the system (4 beeps), and it will then
be possible to reduce the system by pressing the "S" button on the supplied remote control.
- If the "S" button is pressed directly, the system will emit 1 beep and the corresponding partialisation will take place (see above).
Each sensor can only be stored in one zone.
The maximum number of sensors that can be paired for each zone is as follows:
ZONE 1: IR SENSORS AND MAGNETIC CONTACTS 6 UNITS
ZONE 2: IR SENSORS AND MAGNETIC CONTACTS 6 UNITS
ZONE 3: IR SENSORS AND MAGNETIC CONTACTS 10 UNITS
ZONE 4: REMOTE CONTROLS 6 UNITS