ManualP6040 V30Page 6/12
Introduction to P6040 V30
2.3 Intended use
The product is used for creating vacuum or
blow.
2.4 Misuse
Do not use the product for evacuating solid
content without the use of filter.
Do not install or use the product if it is
damaged.
Do not install the product in a fully closed
compartment, without ventilation and exhaust
channeling.
Do not use the equipment as a stand-alone unit
to fulfill international lifting standards.
Do not use blow-off functions or ejector
exhaust for pressurizing components such as
cylinders and/or tank-volumes.
Do not use compressed air pressure or electrical
voltage outside the specification.
Do not use the product for evacuating liquids.
Do not use the product for evacuating
hazardous substances and/or gases without
containing and handling the exhaust flow in a
proper way.
Do not use the product if the exhaust is
restricted or blocked.
Do not use the product if vacuum and exhaust
port are simultaneously blocked when unit is
generating vacuum.
Do not use the product if the compressed air
line is not properly secured.
3. Introduction to P6040
V30
3.1 Manufacturer
Piab AB
P.O. Box 146
SE-18212 DANDERYD
SWEDEN
3.1.1 Identification label
Each unit is identified by a label with identification
information. For any communication with Piab AB or
service centers always refer to the label information.
3.2 Function specification -
On/Off and ES
The P6040 Function Valve V30 is used for On/
Off control.
The P6040 Function ES Vacuum/Blow uses
a vacuum or pressure switch, depending on
application. Vacuum/pressure level can be
adjusted on the switch (A/E).
The working sequence is to start the pump
with the On signal and when the set level is
established, the ES turns the valve off, thus
overriding the On/Off signal.
Status of air valve is displayed by the LED
indicator (B).
In case the ES switch is not connected, the On/
Off will work as a normal V30.
Operating pressure sensing port (O.P).
1 year warranty