26
Installation mode
Standard 35mm DIN rail
Operating environment
Operating temperature: -10~+55
Storage temperature: -40~+70
Relative humidity: 5%~95%,non-condensing
Electrostatic discharge immunity test
IEC61000-4-2,Level 4
Radiated immunity test
IEC61000-4-3,Level 3
Electrical fast transient/ burst immunity test
IEC61000-4-4,Level 4
Surge immunity test (1,2/50μs~8/20μs)
IEC61000-4-5,Level 4
Conducted Emission test
EN55022, Class B
Radiated Emission test
EN55022, Class B