EasyManua.ls Logo

Pilz PSEN cs3.1b - Unit Features; Safety Device Diagnostics (SDD)

Pilz PSEN cs3.1b
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PSEN cs3.1a/b
Operating Manual PSEN cs3.1a/b
1003295-EN-08
| 9
Unit features
} Transponder technology for presence detection
} Pilz coding type: Coded
} Dual-channel operation
} 2 safety inputs for series connection of multiple safety switches
} 2 safety outputs
} Safety Device Diagnostics (SDD)
Safety Device Diagnostics can be used to poll sensor information, to perform actions
and to read configuration parameters
Manipulation protection in accordance with ISO 14119 is possible by verifying the
short name of the actuator through the controller via SDD communication
} Diagnostic input for Y1 for Safety Device Diagnostics (SDD)
} Signal output/diagnostic output Y32 for Safety Device Diagnostics
} LED display for:
State of the actuator
State of the inputs
Supply voltage/fault
} 1 direction of actuation
} Connection types:
PSEN cs3.1a: Cable, 5 m
PSEN cs3.1b: Cable, 10 m