Do you have a question about the Pilz PSEN ma1.4p-50 and is the answer not in the manual?
Connection | Cable |
---|---|
Operating Voltage | 24 V DC |
Safety Category | Category 4 |
Material | Plastic |
Temperature Range | -25°C to +70°C |
Performance Level | PL e |
Protection Class | IP67 |
Ambient Temperature | -25°C to +70°C |
Specifies the validity period of the product documentation.
Guidance on how to read and use the operating manual effectively.
Explains the meaning of DANGER, WARNING, CAUTION, and NOTICE symbols.
Defines the safe operational purpose of the safety switch.
Outlines regulatory requirements, including safety assessment.
Details the necessity of a safety assessment for device usage.
Specifies requirements for competent persons handling the product.
Conditions under which warranty and liability claims are invalidated.
Guidelines for the safe and compliant disposal of the product.
Critical safety warnings and precautions for safe operation.
Lists key technical specifications and components of the safety switch.
Describes the physical design and magnetic operation principle.
Explains how the safety switch functions when the actuator is present.
Illustrates the internal connections of the safety switch.
Details assured operating distances for PSEN ma1.4-03 with offsets.
Details assured operating distances for PSEN ma1.4-10 with offsets.
Instructions for calculating maximum cable length and EMC compliance.
Shows the pin configuration of the safety switch connector.
Specifies requirements for connecting evaluation devices.
Lists compatible Pilz evaluation devices for safety gate monitoring.
Defines required properties of evaluation devices and risk time factors.
Provides general advice on mounting, materials, and potential issues.
Step-by-step guide for installation type 1.
Step-by-step guide for installation type 2.
Guidance on correct actuator compatibility and function testing.
Instructions for performing regular function tests on the safety switch.
Provides the physical dimensions of the safety switch unit.
Covers certifications, mode of operation, and coding level.
Details supply voltage, switching frequency, and contact ratings.
Specifies ambient temperature, humidity, and EMC requirements.
Lists assured and typical operating/release distances.
Covers actuator types, hysteresis, connection, and material.
Provides the physical dimensions of the actuators.
Provides B10d and TM values for safety assessment.
Lists product types, features, connection types, and order numbers.
Lists available connecting cables with different lengths and types.
Lists adapters and modules for connecting the safety switch.
Confirms compliance with European machinery directives.
Provides contact details for technical support worldwide.