MODEL NUMBERS:
MH-45-KFA / MH-80T-KFA / MH-140T-KFA / MH-190T-KFA / MH-215T-KFA
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure
to comply with the instructions and warnings provided with this heater. Failure to comply
can result in fire or explosion that can cause property loss, bodily injury, or loss of life. Only
persons who can follow and understand these instructions should operate or service this
heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle
Climate Technologies at 800-641-6996.
DANGER
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN
ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY
FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR
STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented
portable heater that uses air (Oxygen) from within the area in which it is used. Failure to
provide adequate combustion and ventilation air will result in asphyxiation, carbon monoxide
poisoning, bodily injury or death. Refer to “Ventilation” on Page 6.
FACTORY ID: 001
DANGER
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
© 2019 Pinnacle Climate Technologies, Inc. MAKK-424
User’s Manual &
Operating Instructions
KEROSENE FORCED AIR
HEATER
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Example:
150812779. Have your Serial Number ready before calling customer service at 800-641-6996.

Questions and Answers

  • P
    Patrick BrooksAug 17, 2025
    Why does my Pinnacle Master MH-45-KFA Heater have poor combustion and soot?
    • M
      Matthew BrownAug 17, 2025
      Poor combustion and excess soot production in your Pinnacle Heater can stem from several issues. Check the air or lint filter and clean or replace it if it's dirty. Similarly, a dirty fuel filter should be cleaned or replaced. The fuel quality itself might be the problem; try flushing the fuel tank and refilling with fresh, high-quality fuel. Ensure that the pressure is correct. Lastly, a dirty nozzle can cause this issue, so clean or replace it.
  • S
    Stephanie PalmerAug 23, 2025
    What to do if my Pinnacle Master MH-45-KFA Heater won't turn on and the lamp is not lit?
    • M
      matthewwoodAug 23, 2025
      If your Pinnacle Heater doesn't turn on and the lamp isn't lit, first, ensure the temperature limit sensor hasn't overheated. Turn the power switch to 'OFF,' let the heater cool for 10 minutes, and then restart it. Check that the power cord is properly connected and test the power supply. Also, inspect the fuse and replace it if it's blown.
  • J
    Jessica MontoyaAug 28, 2025
    What to do if my Pinnacle Master MH-45-KFA won't operate and shows error E1?
    • A
      Alicia WatkinsAug 29, 2025
      If your Pinnacle Heater won't operate and the LED display shows “E1”, start by checking if there is kerosene in the fuel tank and fill it with fresh kerosene if needed. Ensure the pump pressure is correct by adjusting it. Inspect the spark plug for corrosion or incorrect gap and clean or replace it. A dirty fuel filter or nozzle could also be the cause, so clean or replace them. If there's moisture in the fuel tank, rinse it with clean, fresh kerosene. Make sure the ignitor wire is connected to the spark plug and that the rotor spacing is correct. If the ignitor is defective, replace it.
  • M
    Mary McdanielSep 4, 2025
    What does it mean when my Pinnacle Heater lamp is flickering and the LED display shows “E3”?
    • A
      Amanda BennettSep 4, 2025
      If the lamp is flickering and the LED display shows “E3” on your Pinnacle Heater, it indicates that the thermostat switch has failed and needs replacement.
  • S
    Sean MorrisonNov 10, 2025
    What to do if my Pinnacle Master MH-45-KFA ignites, but shuts off with error E1?
    • J
      Joshua MartinNov 10, 2025
      If your Pinnacle Heater ignites but the main PCB shuts off shortly after, displaying error code E1, there are several potential causes. It could be due to incorrect pump pressure, which requires adjustment. Another reason could be a dirty input, output, or lint filter, needing cleaning or replacement. A dirty fuel filter or nozzle can also cause this issue, so inspect and clean or replace them as necessary. Other potential causes include a dirty or improperly installed photocell or a defective photocell, which should be cleaned, adjusted, or replaced. Check wiring connections between the main PCB and the photocell, as well as the thermister placement (excluding the 45-KFA model). Finally, an improper electrical connection within the temperature limit switch may be the problem; consider rep...