CONDENSING UNITS
RevisionB:ODMIC11310
ModelNumbers:
YN018GMFI16M2D(Dual) YN030GMFI16M3D(Trio)
YN027GMFI16M3D(Trio) YN036GMFI16M4D(Quad)
WARNING
Installation MUST conform with local building codes or, in the absence of local
codes, with the National Electrical Code NFPA70/ANSI C1-1993 or current edition
and Canadian Electrical Code Part1 CSA C.22.1.
The information contained in the manual is intended for use by a qualified service
technician familiar with safety procedures and equipped with the proper tools and
test instruments
Installation or repairs made by unqualified persons can result in hazards to you
and others.
Failure to carefully read and follow all instructions in this manual can result in
equipment malfunction, property damage, personal injury and/or death.
Table of Contents
1. Product Specifications
2. Indoor Unit Combination
3. Suggested Indoor Unit Model Numbers
4. Dimension Of Outdoor Unit
5. Refrigerant Cycle Diagram
6. Installation Details
7. Electronic Function
8. Wiring Diagrams And Electrical Trouble Shooting
9. Disassembly Instructions
10. Exploded View
YN-M SERIES MULTI SPLIT SYSTEM
MULTI CIRCUIT OUTDOOR UNITS
(2, 3 AND 4 ZONES) SERVICE MANUAL 
2014ANDNEWERMODELS(50130070AND
NEWERSerials)
Parker Davis HVAC International, Inc.
2260 NW 102nd Place, Doral, FL 33172
Ph: (305) 513-4488 info@pd-hvac.com

Table of Contents

Questions and Answers:

Pioneer YN027GMFI16M3D Specifications

General IconGeneral
BrandPioneer
ModelYN027GMFI16M3D
CategoryAir Conditioner
LanguageEnglish

Summary

Product Specifications

YN018GMFI16M2D Specifications

Specifications for the YN018GMFI16M2D Dual Zone (18K Nominal) outdoor unit.

YN027GMFI16M3D Specifications

Specifications for the YN027GMFI16M3D Triple Zone (27K Nominal) outdoor unit.

YN030GMFI16M3D Specifications

Specifications for the YN030GMFI16M3D Triple Zone (30K Nominal) outdoor unit.

YN036GMFI16M4D Specifications

Specifications for the YN036GMFI16M4D Quad Zone (36K Nominal) outdoor unit.

Indoor Unit Combinations

Dual Zone 18K Combination

Suggested indoor unit combinations for the 18K Dual Zone outdoor unit.

Triple Zone 27K Combination

Suggested indoor unit combinations for the 27K Triple Zone outdoor unit.

Triple Zone 30K Combination

Suggested indoor unit combinations for the 30K Triple Zone outdoor unit.

Quad Zone 36K Combination

Suggested indoor unit combinations for the 36K Quad Zone outdoor unit.

Suggested Indoor Unit Models

YN018GMFI16M2D Indoor Models

Lists suggested indoor units for the YN018GMFI16M2D outdoor unit.

YN027GMFI16M3D Indoor Models

Lists suggested indoor units for the YN027GMFI16M3D outdoor unit.

YN030GMFI16M3D Indoor Models

Lists suggested indoor units for the YN030GMFI16M3D outdoor unit.

YN036GMFI16M4D Indoor Models

Lists suggested indoor units for the YN036GMFI16M4D outdoor unit.

Outdoor Unit Dimensions

YN018GMFI16M2D Dimensions

Physical dimensions for the YN018GMFI16M2D outdoor unit.

YN027GMFI16M3D Dimensions

Physical dimensions for the YN027GMFI16M3D outdoor unit.

YN030GMFI16M3D Dimensions

Physical dimensions for the YN030GMFI16M3D outdoor unit.

YN036GMFI16M4D Dimensions

Physical dimensions for the YN036GMFI16M4D outdoor unit.

Refrigerant Cycle Diagrams

5.1 Dual Zone Refrigerant Circuit

Refrigeration circuit diagram for 2-zone inverter multi-split systems.

5.2 Triple Zone Refrigerant Circuit

Refrigeration circuit diagram for 3-zone inverter multi-split systems.

5.3 Quad Zone Refrigerant Circuit

Refrigeration circuit diagram for 4-zone inverter multi-split systems.

Installation Details

6.1 Wrench Torque Sheet

Specifies torque values for installation connections.

6.2 Connecting the Cables

Details power cord and indoor/outdoor unit connection wire specifications.

6.3 Pipe Length and Elevation

Maximum refrigerant piping lengths and height differences.

6.4 First-Time Installation

Procedures for first-time installation, including leak testing.

System Evacuation and Purging

Evacuation using a Vacuum Pump

Step-by-step guide for system evacuation using a vacuum pump.

Air Purging by Refrigerant

Procedure for purging air from the refrigerant system.

Refrigerant Charging Procedures

Adding Refrigerant for Pipe Length

Guidelines for adding refrigerant based on pipe length.

Adding Refrigerant After Long Use

Guidelines for adding refrigerant after the system has run for many years.

Unit Re-installation

Indoor Unit Re-installation After Repair

Steps for re-installing the indoor unit after repair.

Outdoor Unit Re-installation After Repair

Steps for re-installing the outdoor unit after repair.

Electronic Function

7.1 Abbreviations

Definitions of technical abbreviations used in the manual.

7.2 Operating Environment

Specifies voltage, frequency, and current limits for operation.

7.3 Main Protection Functions

Details protection mechanisms like time delay, temp, and fan speed.

7.3.4-7.3.12 Other Protections

Covers inverter, compressor, communication, and environmental protections.

7.4 Control and Functions

Explains capacity request calculation and operating frequency confirmation.

7.4.2 Defrost Control Logic

Details the conditions and actions for defrost cycle management.

7.4.3 Outdoor Fan Control Logic

Describes fan speed control strategies in cooling and heating modes.

7.4.4 EXV Control

Explains the operation of Electronic Expansion Valve.

7.4.5 Four-Way Valve Control

Explains the operation of the four-way valve.

Wiring Diagrams

8.1 DUAL Circuit Outdoor Unit Wiring

Wiring diagram for the YN018GMFI16M2D dual circuit outdoor unit.

8.2 Triple Circuit Outdoor Unit Wiring

Wiring diagrams for YN027GMFI16M3D and YN030GMFI16M3D triple units.

8.3 Quadruple Zone Outdoor Unit Wiring

Wiring diagram for the YN036GMFI16M4D quadruple zone outdoor unit.

Troubleshooting Guide

9.1 Safety Precautions

Important safety warnings regarding high voltage and capacitor discharge.

9.3 Outdoor Unit Display and Errors

Explains outdoor unit digital display functions and error codes.

9.4 Diagnosis and Solution

Detailed troubleshooting steps for common malfunctions.

9.4.1 Indoor Unit Troubleshooting

Troubleshooting for indoor unit issues like EEPROM and communication errors.

9.4.2 Outdoor Unit Troubleshooting

Troubleshooting for outdoor unit issues like EEPROM and communication errors.

Disassembly Instructions

YN018GMFI16M2D Disassembly

Step-by-step guide to disassemble the YN018GMFI16M2D outdoor unit.

YN030GMFI16M3D Disassembly

Step-by-step guide to disassemble the YN030GMFI16M3D outdoor unit.

YN036GMFI16M4D Disassembly

Step-by-step guide to disassemble the YN036GMFI16M4D outdoor unit.

YN036GMFI16M4D Disassembly (Cont.)

Step-by-step guide to disassemble the YN036GMFI16M4D outdoor unit.