BEFORE SERVICING, REFER TO PAGE 3 AND 4 OF THIS DOCUMENT FOR IMPORTANT NOTICES
11 L22-405
COMPUTER DISPLAYS
•
During the lter cycle, the system automacally closes the drain. If there is debris or tools in the drain when it
aempts to close it, the drain will not close correctly and give you this message.
Remove any debris or tools from the drain and press the “6” key to try closing the drain again.
If all debris and tools have been removed, the drain will close and the lter process will connue.
You have three aempts to retry closing the drain. Aer the third failed aempt at closing the drain, the
fryer will shut down and will display “ ”. Do not
power cycle the fryer at this me as repeated aempts to close the drain may cause damage if the debris is
not properly cleared. The drain manifold should be dismantled to clear any clogs. If the tank needs to be
drained to remove the clog, an alternate draining method must be used.
•
The drain aempted to close three mes and never was sensed closed. Service will need to be scheduled. Do not
power cycle the fryer at this me as repeated aempts to close the drain may cause damage if the debris is not
properly cleared.
• or
The fryer must be ltered before any further cook mers can be started.
•
JIB stands for Jug In Box and is referring to the container of oil in the cabinet of the fryer.
If you have a single fryer, the JIB is the metal slide out box that must be manually lled with oil.
If you have a dual fryer, the JIB is the plasc jug of fresh oil located in the le-hand fryer cabinet.
This message indicates the JIB is geng low on oil and will need to be relled/changed soon.
•
JIB is empty and needs to be lled/changed.
To reset the error, ll or change the JIB and then press and hold the clock key on the controller unl
is displayed and then press the “6” key for yes.
•
The fryer is trying to take fresh oil from the JIB but it is not able to.
Rell or replace the JIB and then reset the JIB mer.
Make sure the pump circuit breaker is in the “ON” posion.
•
This is usually due to a tripped hi limit or low oil level causing the liquid oat switch to open.
Turn the fryer o. Press the reset buon for the hi limit switch, located next to the remote USB port.
Verify proper oil level in the tank and the turn the unit back on to see if normal operaon returns.
If normal operaon did not return, check troubleshoong steps for the relay board heat circuit.
•
Temperature probe is not being sensed by the controller.
Refer to temperature probe troubleshoong in this manual.
•
A short to ground on the temperature probe circuit has been detected. Check the probe circuit and the temperature
probe for shorts to ground using a mulmeter.
•
The controller is detecng the oil temperature has reached 40°F (22°C) above set point or 410°F (210°C),
•
Drain is not sensed closed when the unit is turned on. Refer to drain actuator troubleshoong in this manual.
•
A communicaon failure has occurred between the controller and relay board. Power cycle the unit.