Piusi K900 User Manual

Piusi K900
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation, use and calibration | EN
Installazione, uso e calibrazione | IT
K900
Bulletin M0158b IT | EN _00

Other manuals for Piusi K900

Question and Answer IconNeed help?

Do you have a question about the Piusi K900 and is the answer not in the manual?

Piusi K900 Specifications

General IconGeneral
CategoryMeasuring Instruments
Inlet/Outlet1" BSP
TypeFlow Meter
Accuracy±0.5% after calibration
Operating Temperature-10°C / +60°C
ModelPiusi K900

Summary

DECLARATION OF CONFORMITY

GENERAL WARNINGS

SAFETY INSTRUCTIONS

SAFETY WARNINGS

Avoid electrical contact with fluid; disconnect power before maintenance.

FIRST AID RULES

Procedures for eye/skin contact, inhalation, or ingestion of treated product.

GENERAL SAFETY RULES

Use appropriate protective equipment suited to operations and cleaning agents.

PACKAGING

PACKAGE CONTENTS/PRE-INSPECTION

Verify package contents against specifications; contact supplier for any anomalies.

BECOMING ACQUAINTED WITH K900

LCD DISPLAY (ONLY METER VERSION)

Details the two numerical registers and various indications displayed on the LCD screen.

USERS BUTTONS

INSTALLATION

ELECTRICAL CONNECTION

Diagrams and notes for electrical connections of the K900 with optional components.

DAILY USE

DISPENSING IN NORMAL MODE

Describes the standard dispensing mode and display behavior after dispensing ends.

PARTIAL RESET (NORMAL MODE)

Details how to reset the partial register when the meter is in standby.

RESETTING THE RESET TOTAL

ERROR INDICATIONS

CALIBRATION

DEFINITIONS

Defines "Calibration factor" or "K Factor" and "User K Factor".

CALIBRATION PROCEDURE

Outlines why and how to calibrate the meter, mentioning two procedures.

DISPLAY OF CURRENT CALIBRATION FACTOR AND RESTORING FACTORY FACTOR

IN FIELD CALIBRATION

IN-FIELD CALIBRATION PROCEDURE

Step-by-step guide for performing in-field calibration using the meter's buttons and display.

DIRECT MODIFICATION OF K FACTOR

CONFIGURATION

CONFIGURATION OF THE UNITS OF MEASUREMENT

Explains how to select the main measurement unit for the meter.

(OPTIONAL) PULSE TRANSMITTER (PULS OUT)

ALARM OUTPUT (ALARM OUT)

MAINTENANCE

CHANGE BATTERY

Instructions for replacing the meter's batteries and low-battery alarm levels.

CLEANING THE MEASUREMENT CHAMBERS

CLEANING THE FILTER

DISPOSAL

MALFUNCTIONS

TECHNICAL SPECIFICATIONS

EXPLODED VIEW / SPARE PARTS

Related product manuals