Mounting of the motor shall be performed on a firm base with an
appropriate number of bolts. Please refer to the Appendix for
recommended bolt sizes and torque. Depending on the model, the
motor may be specified for front mounting, back mounting or both.
Please contact us for any questions on mounting and installation.
Only motor controllers and regulators approved by Plettenberg must be
used. If other motor controllers or regulators are used, Plettenberg
cannot assume any guarantee or liability in the event of destruction of
the motor, regulator or the motor controller.
Motor connection cables must never be shortened or extended.
The three motor phases must be connected to the motor controller
according the manufacturer´s instructions.
The sensor cable must be connected to the motor controller in
accordance with the manufacturer´s specifications.
Additionally required tools/materials
(not included)
No-clean lead-free solder
Heat shrink tubing
Cable
Soldering iron rated at least 100 W
Hot air gun
A wide portfolio of flexible high temperature cables of different
cross-sections, colors and requirements is available from
Plettenberg. For more information, please reach out to
sales@plettenbergmotors.com.
The motor phases must not be shortened without prior
consultation. Crimping of connections must also not be
executed without previous consultation.
Cable connections
Soldered
connections
Destruction of / damage to the motor due to poor-quality or
high-resistance connections.
Burns
Caused by carelessly touching hot surfaces.