OM_Plettenberg_Electric_Motors | Version 1 | 2023.07.14 17
thermal simulation. For applications with insufficient or non-ideal
airflow, Plettenberg has a wide range to active and passive cooling
solutions available.
For water-cooled motors, Plettenberg recommends minimum flow
of 7 litres-per-minute at max. 40 degrees Celsius inlet temperature.
Coolant pressure shall not exceed 2 bar/ 29 PSI. For specific
pressure drops by motor type please reach out to us.
Plettenberg motors of the NOVA series are equipped with a
temperature sensor. The sensor measures the temperature in the
stator, which shall never exceed 100 degrees Celsius.
All fastening screws or bolts for the motor must be checked for
tightness before commissioning.
It needs to be ensures that all energized cables, plugs and sockets
are insulated so that unintentional switching on of the motor by cable
contact is prevented.
5. Maintenance
The housing surfaces can be cleaned with compressed air and a
dry, lint-free cloth.
The maintenance requirements can vary by the type of motor.
Please consult sales@plettenbergmotors.com for detailed
information on requirements.
6. Disposal
A motor that has reached the end of its service life is electrical scrap.
Electrical scrap consists of valuable materials, which can be
recovered as secondary raw materials, but also of environmentally
hazardous substances.
Information regarding optimum material recycling is available from
commercial waste disposal companies.