OM_Plettenberg_Electric_Motors | Version 1 | 2023.07.14 13
4. Commissioning
Thermal overload / destruction
Always ensure sufficient cooling for the motor (air or water
cooling)
A high load on the motor is only permissible in short operation.
Under no circumstances must the motor exceed the
temperature of 100°C.
Only motor controllers and regulators approved by
Plettenberg must be used.
Safety during
commissioning
Severe, moderate or minor injuries.
Destruction or damage to the product
Safety instructions from Chapter 2 must be complied with!
Test runs with prop should only be executed outdoors or with
special safety equipment, such as caged test stand.
The side and front of the rotating plane needs to be kept clear.
Assembly &
mounting
Destruction / damage of the motor
Always use suitable screws or bolts.
Sawed or ground screws or bolts can destroy the thread in the
motor’s bearing shield.
After each use, the motor must cool down again to ambient
temperature.
Only motor controllers and regulators approved by Plettenberg
must be used.
Never exceed the maximum screw-in depth. Screws or bolts
which are screwed too far will damage or destroy the motor.
Only use original screws or bolts.
Do not use a sensor-guided motor against its specified
direction of rotation.