Loading...
EN
11
III. DELETE CLEAR ALL PAIRING
On receiver unit press and hold both pairing and On/Off buttons for 5 seconds until LED1 and LED2 turn
on. Release buttons.
Then LED 1 turns off, which means that all pairing have been cleared.
IV. SIGNAL LOST OR WEAK
In case the RF and WIFI signal lost/disconnected, LED 2 will icker slowly.
Move units closer to each other and the WiFi router and check the status of the devices again.
If within a few minutes the operation does not return to normal, delete all pairing and perform the pairing
procedures of receiver, main unit, and the wireless router (with the mobile application) again.
HOUR/DATE SETTING
With main unit screen On, press and hold the M button for 5-6 seconds until the hour on the screen blinks.
You will see highlighted 00:00 on the screen. Set the minutes with the up and down buttons.
Continue pressing the M button.
Set the time with the up and down buttons.
Continue pressing the M button.
Select the day with the up and down buttons.
Continue pressing the M button.
Save the settings by pressing the ON / OFF button or wait about 15 seconds.
OPEN WINDOW DETECTION FUNCTION
When the “open window” detection mode is activated in advanced settings, the system will automatically
switch off heating if a sudden decrease in temperature (2°C in 15 minutes by default) occurs. This function is
useful when opening a door / window (eg ventilation) without stopping the heating.
The thermostat will return to previous working mode after 30 minutes, and the “OP” icon will disappear from
the screen. Press any button and thermostat will exit OWD function, during the heating off period.
OTHER FEATURES AVAILABLE IN YOUR SMARTPHONE APPLICATION
In TuyaSmart app you have the following features available:
- Measured temperature and programmed / set temperature by user;
- Heating Status: The “Heating” text appears on screen when the heat is on;
- 3 working modes: manual, Eco (economical) and automatic (according to daily schedule)
- Child lock function- Thermostat keyboard lock to stop accidental push of buttons
- Daily schedule (7 days) with 4 hour zones every day;
- Scheduled temperature timing
SET UP DAILY PROGRAMS
This setup n can also be done from smartphone app, wich we recommend.
With the on-screen display, press and hold the P button (6-7 seconds) to enter the PROGRAM settings. Days
of the week are xed from Monday to Sunday (1 ~ 7), each day has 4 time periods (1 ~ 4). Each press of the
P button can be performed in the next setting.
1). Press P and hold for 3 seconds, the “hour” display ashes, change the value with the + and - buttons.
2) Press the P button, the temperature blinks, change the desired temperature with the + and - buttons.
3). Press the P button for the next time.
4). Repeat the settings for the other days and periods similarly.