EasyManua.ls Logo

PNI CT35 - Technical Specifications and Unit Descriptions; System Technical Specifications; Main Unit Display and Controls; Receiver Unit Functionality

PNI CT35
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
9
TECHNICAL DETAILS / SPECIFICATIONS
- Main unit power supply: 2 AAA batteries
- Receiver power supply: 230VAC 50 / 60Hz
- Receiver unit command type: NO Relay (normally open) 10 Amps max
- Set point range temperature: 5 - 35
o
C
- Measurable ambient temperature: 0 - 50
o
C
- Temperature measurement unit: only
o
Celsius degrees
- Acceptable humidity: 85% no condensation
- Screen illumination: white light
- Temperature sensor: NTC 10K, 3950ohms at 25
o
C
- Sensor accuracy: ± 0.5 °C (adjustable by 0.5 °C step sensor calibration)
- Protection degree: IP30
- Housing: ABS with UL94-5 re retardant plastic standard
- WiFi connectivity: 802.11 b / g / n (2.4 GHz); WPA2 (TKIP and AES)
- RF frequency connectivity between units: 868 MHz
- Smartphone Compatibility: Minimum iOS 9 / minimum Android 4.2
MAIN UNIT DESCRIPTION
RECEIVER DESCRIPTION
Weekday
Clock
Set Temp.
Heating Icon
Battery indicator
Room Temp. Display
Programmable Period
Prg. Button
Modes select
On/O Button Temp. and parameters settings
On/O Button
Code pairing Button
Heating On Indicator ( LED 1)
Power Indicator ( LED 2)