55
OPERATION
Pre- Operation Check
n Jet Pump Intake
1. Ride Plate 2. Impeller
3. Drive Shaft 4. Intake Grate
The lanyard lock plate must be removed from t he stop switch. Battery
cables must also be disconnected before continuing this inspection.
Carefully check the jet pump intake for debris such as weeds, shells or
anything which may restrict the intake of water. Damage could occur if
the intake is clogged, causing engine overheating and jet pump
damage. If any obstruction cannot be removed have an authorized
Polaris dealer service it immediately.
After launching, walk the watercraft into water at least 2 feet (60 cm)
deep and bounce the back of the watercraft up and down several times
to flush out any sand and debris that may be in the pump.
1
2
3
4
Ingestion of sand into the cooling system will cause the engine to
overheat, resulting i n possible severe engine damage.
CAUTION