Measured
Temperature
Precision: 0.1°C
Environmental
Operating Temperature: 0°C - 40°C
Shipping and Storage
Temperature: -10°C to +50°C
Setting Temperature
Range
Comfort, Reduced: 5°C to 35°C
by 0.5°C step
Anti freeze/OFF: 7°C
Holiday: 0.5°C to 20°C
Timer: 5°C to 35°C
Regulation
Characteristics: Hysteresis of 0.5°C
Electrical
Protection: Class II - IP30
Power Supply:
2 AAA LR03 1.5V
Operating Life: Alkaline
2 Years
Output: 2 Points Contact
(Free Contact)
Relay 5 Amps 250Vac
Optional External
Sensor: 10k ohms at 25°C
7 Technical Specification
8 Fault Diagnostics
My thermostat doesn’t start
Battery - Check if the protection sticker
Problem on the batteries is removed.
- Check the orientation of the batteries.
- Check the charge of the batteries.
My thermostat LED, blinks in red
Problem The logo blinks (ambient sensor)
on Sensors - Contact your installer.
The logo blinks (floor sensor).
- Check the connection
of the sensor.
- Disconnect the sensor, and check
it with an ohmmeter (the value
must be around 10kohms).
Battery The logo blinks (batteries)
level is low - Replace the batteries.
My thermostat seems work correctly but
the temperature in the room was never
in accordance with the program
Program - Check the clock.
- Check the difference between
Comfort and Setback temperature
is not too high?
- Contact your installer, to check
and adjust the calibration.
06