E2
Seal Mode Failure
Ensure that the Vacuum Chamber Lid is
fully closed
Check the Vacuum Chamber Lid Gasket
for any gaps, damage or debris
Disconnect hose from the External
Vacuum Port, if attached
Contact dealer or factory
LP
Electrical Power
Failure
Press to return the Chamber Vacuum
Sealer to its previous operating
parameters (last selected Vacuum
Level, Marinate Time and Seal Time). 00
will appear on the Digital Display.
Vacuum
Level
(LED lights)
Time
(seconds)
InHg
(Inches of
Mercury)*
Torr
(Millimeters of
Mercury)*
InHg
(Gauge
Inches of
Mercury)**
Torr
(Gauge
Millimeters of
Mercury)**
Maximum
30-45
0.35
9
-29.55
-750
High
22.8
1.02
26
-28.88
-733
Medium
17.3
2.24
57
-27.66
-702
Low
13.2
4.09
104
-25.81
-655
Minimum
10
6.42
163
-23.48
-596
* Values are approximate and based on an ambient temperature of 25ºC (77ºC) at sea level (29.9 In Hg / 760 Torr).
** Gauge vacuum equivalents are listed to provide a reference to vacuum sealers with vacuum gauges.